Smeg K9998 Instrucciones Para Instalación Y Uso página 2

Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 13
ENGLISH
Warning: Failure to install the screws or fixing device in accordance with these instructions may result in
electricalhazards.
If the supply cord is damaged, it must be replaced by the manufacturer, its service agent or similarly qualified persons
in order to avoid a hazard.
Only for hoods equipped with electronic control:
The 4th speed (intensive) is automatically lowered to 3rd speed after 5 minutes of operation to optimise energy consumption.
- If the hood is left on (lights and/or motor), after 10 hours in the absence of commands from the user, it will automatically
switch to OFF condition with all services switched off.
- The Buzzer emits a "beep" each time that a command is set from the keyboard or remote control (optional).
- In the event of interruption of power during the hood, if you restore the hood in the OFF state, then the engine must
be reactivate manually.
DESCRIPTION
The hood may be in the filtering or the ducting version.
Filtering version (Fig. 1): The hood aspirates the kitchen air saturated with fumes and odours, purifies it through
the grease filter/s and charcoal filter and returns clean air into the room. For constant efficiency, the charcoal filter must
be replaced periodically. The charcoal filter is not supplied.
Ducting version (Fig. 2): The hood aspirates the kitchen air saturated with fumes and odours, passes it through the
grease filter/s and expels it to the outside through an outlet pipe. With this version the charcoal filter is not required. Decide
from the outset on the type of installation (filtering or ducting). For greater efficiency, we recommend you install the hood
in the ducting version (if possible).
INSTALLATION
ATTENTION: Two persons are required for proper installation; the unit should be installed by a qualified operator.
INSTALLATION IN DUCTING VERSION: Before fixing, the outlet pipe for air evacuation to the outside must be installed.
Use an outlet pipe with: – minimum indispensable length; – minimum possible bends (maximum angle of bend: 90°); – certified
material (according to the State); – an as smooth as possible inside. It is also advisable to avoid any drastic changes
in pipe cross-section (recommended diameter: 150 mm). For air evacuation to the outside, follow all the other instructions
given on the "Warnings" sheet. Prepare the power supply within the telescopic chimney (for the electrical connection, follow
all the other instructions on the "Warnings" sheet).
1.
Fixing to the wall: Draw a line on the wall in vertical line with your hob. Mark the first 2 holes to be drilled in the
wall, respecting the distances indicated in Fig. 3. Drill the 2 holes and fit the screw anchors provided.
Bear in mind that the distance between the lower edge of the hood and the hob must be min. 484 mm. Fix the metal bracket
(A) to the wall using the 2 holes just drilled (Fig. 4); the screws for fixing the bracket are provided. Use the 2 cut-out triangles
on the bracket to position it exactly along the vertical axis of the hood. Hang the hood on the bracket (Fig. 5). Adjust
the horizontal position moving the hood to the right or left so that it is aligned with the wall units. When adjustment has
been completed, without removing the hood, mark the other 4 holes to be drilled (C) in the wall. Remove the hood and
drill the holes marked (8 mm diameter). Then use the 4 screw anchors and the 4 screws provided for final fixing.
2.
Install the flange in the device air outlet and press slightly (Fig.6).
3.
Fixing the telescopic flues:
3a - Adjust the width of the support bracket of the telescopic flue by means of the screws as shown in Fig.7; then, by
means of the screw anchors and screws (F) provided, fix the bracket to the ceiling in such a way that it is positioned along
the axis with your hood (Fig.8).
3b - Connect the air outlet pipe to the air vent of the hood. - Use a flexible pipe and lock it to the air vent of the hood
with a metal hose clamp - Fig. 9 (pipe and clamp are not provided). - For exhaust hoods, turn the upper flue over so that
the air exhaust grid is in the lower section (Fig. 10).
3c - Plug in the hood. Insert the extension flues setting them on the hood; extend the upper flue to the ceiling and secure
with the 2 screws (H) - Fig. 11.
4.
BE CAREFUL WITH THE CHARCOAL FILTER/S. In the ducting version, the charcoal filter/s do not have to
be used, therefore, if already installed in the hood, remove it/them as described in the paragraph "Removing the charcoal
filter".
INSTALLATION IN FILTERING VERSION: Prepare the power supply within the telescopic flues (for the electrical
connection, follow all the other instructions on the "Warnings" sheet).
BE CAREFUL WITH THE CHARCOAL FILTER/S. In the filtering version, the charcoal filter/s have to be used, therefore,
if not yet installed in the hood, fit it/them as described below.
Fitting the charcoal filter: refer to Fig.12, Fig.13 or Fig.14 depending on the model purchased.
Fig.12: Remove the grease filters by pushing the catch towards the rear of the hood and turning the filters outwards.

Publicidad

Tabla de contenido
loading

Tabla de contenido