DIMENSIONS: 307 x 200 x 53mm
13.1 – electrical diagram and connections
CONNECTION TO THE MAINS SUPPLY – device according to Class II
Connection to the mains supply must be carried out in accordance with national regulations, positioning the ferrite provided as illustrated (see
diagram) and using an appropriate resealable terminal. The extremities of the cable conductors must not be strengthened with soft soldering at
the points in which the conductors are subject to contact pressure. The cable must be blocked by tightening the screws in order to prevent it
from becoming detached accidentally. The connection to the electrical mains must provide for an easily accessible bipolar sectioning device with
a distance of at least 3mm between the contacts; or it must end with a standard plug which can be inserted into a socket. Perform any
necessary tests only with the battery which must be charged. Once connections have been completed, close internal cover, close the control
panel and only then activate the sectioning device or connect the plug into the socket.
Note: Always disconnect the 230V mains power supply before intervening on the control panel.
Terminal board (see diagram 3)
SPK
+ALI
+OFF
GND (all):
+SIR
+SAA
+N
A1-2 B1-2 C1-2
TMP A-B-C
KEY
NC1-C1-NO1
NC2-C2-NO2
Telephone
Comments:
1) The alarm and tamper inputs operate Normally Closed and become active at first closure. Therefore, if closed accidentally
they will signal that the line is open. To cancel the signal, go to TEST and then exit.
2) The TMP inputs (tamper) must be programmed on the same zone groups as the relative detectors.
14.0 - Model 5501 SILENYA HT Free GSM - Model 5503 SILENYA HT Free – TECHNICAL CHARACTERISTICS
Note: Model 5503 does not have a GSM module and therefore does not feature GSM functions.
Power supply:
Electrical input:
Autonomy:
(5503)
Alarm inputs
via radio: Up to 99 programmable detectors with immediate, delayed or AND operation on the 3 alarm zone groups (A-B-C)
Anti-tamper
Pre-alarm outputs via radio: 72-bit codified digital transmissions for low-intensity operation of alarm devices
Alarm outputs:
via radio: 72-bit codified digital transmissions for operating all types of alarm devices
Radio noises:
Events memory:
Timed operations:
Display:
Operations:
Built-in siren and buzzer:
Acoustic signals:
Radio receiving-transmitting: Simultaneous DualBand frequency – factory programmed digital codes with self-learning
Radio range:
Wired connection:
DIMENSIONS: 307 x 200 x 53mm
Number/messages table (different action required where there are more than 15 programmed numbers)
SILENTRON – made in Italy
reduced in indoor use due to the position of the devices in relation to the building structure.
WEIGHT: 1,2 Kg
Positive: additional 8 Ohm speaker output for messages from the control panel
Positive: 12V CC max 500mA power supply for wired detectors
Positive: present with disarmed control panel – wired siren blocking command
Ground
Positive: 12V max 500mA in alarm for additional sirens
Positive: 14V (in presence of 230V only) for power supply to internal battery self-powered wired sirens
Falling positive: alarm for wired sirens
Note: If 2 or more sirens are connected, it is obligatory to insert 2 or more
diodes on the terminal in order to avoid return signals.)
Note: Never use this output for siren power supply.
NC alarm inputs
NC self-protection inputs
ON-OFF input for external key (closed = OFF)
Free switch output relay R1 – connect only to circuits with SELV voltage (extremely low safety voltage)
Free switch output relay R2 – connect only to circuits with SELV voltage (extremely low safety voltage)
PSTN line connection
Alkaline pack battery (Powerpack) code 861010 (9V 12Ah)
180 - 220uA in stand-by - max 400mA in alarm with GSM in operation - max 200mA with PSTN in operation
Theoretical without alarms and with 2 arming/disarming operations per day: Approx. 2 years (5502) – then 2 years
Note: Autonomy considerably decreases in the case of numerous alarms and/or telephone calls and/oroperations.
or on the 24-hour zone groups Panic, Robbery, Technical alarm.
via radio: Receipt of tamper signal by each individual detector
Receipt of operating status and low battery signals (SUPERVISION)
Protection against opening/removal of control panel:
Continuous, simultaneous or programmable control of the two working frequencies
Last 200 events (new ones substitute the old ones)
Programmable delayed arming – input delay programmable on every detector
3 minute general alarm time
Display 2 x 16 characters, with possibility of naming each single peripheral device (label)
20-button alphanumeric keypad
106 db alarm siren + buzzer for low intensity warning
Recordable vocal messages for principal communications with user
ability from microprocessor – frequency and power in accordance with the law.
100m in open air and without any background noise on the band – range cover can be slightly
reduced in indoor use due to the position of the devices in relation to the building structure.
PSTN line connection (also ADSL)
WEIGHT: 2 Kg
BOX: ByBlend
BOX: ByBlend
TEMPERATURE: operating/storage -10°+40°C
COPYRIGHT SILENTRON DS5500/1/2/3BA080228GM
TEMPERATURE: operating and storage -10°+40°C
16