1. Unplug all electrical loads from the unit's receptacles
before starting engine.
2. Place generator on a level surface.
3. See Figure 3-2. Open the fuel shut-off valve (A).
4. Turn engine ON/OFF switch (B) to ON. See
Figure 3-2.
A
Figure 3-2.Engine Controls
5. Slide engine choke (C) to Full CHOKE position (left).
See Figure 3-3.
C
6. See Figure 3-2. Firmly grasp recoil handle (D) and
pull slowly until increased resistance is felt. Pull rapidly
up and away.
7. When engine starts,move choke knob to RUN
position. If engine falters, move choke back to 1/2-
CHOKE position until engine runs smoothly,then to
RUN position.
NOTE: If engine fires, but does not continue to run,
move choke lever to Full CHOKE and repeat starting
instructions.
IMPORTANT NOTE: Do not overload generator or
individual panel receptacles. These outlets are overload
protected with pushto- reset circuit breakers. If
amperage rating of any circuit breaker is exceeded, that
breaker opens and electrical output to that receptacle is
lost. Read Know Generator Limits carefully.
Owner's Manual for Petrol Generator
Generator Shut Down
Equipment and property damage. Disconnect electrical
loads prior to starting or stopping unit. Failure to do so
could result in equipment and property damage.
1. Shut off all loads and unplug electrical loads from
generator panel receptacles.
B
2. Let engine run at no-load for several minutes to
stabilize internal temperatures of engine and generator.
3. Move ON/OFF switch to OFF.
4. Close fuel valve.
D
NOTE: Under normal conditions, close fuel valve and
allow generator to run carburetor bowl out of fuel. For
emergencies, switch to OFF.
Low Oil Level Shutdown System
The engine is equipped with a low oil level sensor that
shuts down the engine automatically when the oil level
drops below a specified level. The engine will not run
until the oil has been filled to the proper level. If the
engine shuts down and there is sufficient fuel, check
engine oil level.