• STEP 3 – Fixing the battery in the selected site
After performing the checks specified in section 3.1 - 3.2 establish-
ing the precise position for the battery, fix the latter onto the selected
surface as shown in fig. 6.
6
• STEP 4 – Cable routing
IMPORTANT! – If the power cable in the pack is used outdoors,
it must be entirely protected with special ducting suitable for
the protection of electric cables.
After fixing the panel and battery, route the panel cable through the
tube or protection ducting through to the battery.
With reference to the instruction manual of the automation to be
powered, remove the control unit protection cover. Then pass the
end of the power cable (with wires stripped) through the automation
(where the other cables are routed) and through the dedicated cable
clamp. Then route the cable through the protection ducting (if pre-
sent) through to the battery.
Caution! – Do not connect the power cable to the control unit;
leave access to the control unit open and leave the cable
clamp loose.
• STEP 5 – Assembly of " L" socket on the photovoltaic panel
cable
If the cable is too long, it can be shortened, taking care to strip the
wires so that their length is equal to the values specified in the fig. 7
(caution! – different lengths may impair subsequent assembly of the
socket).
7
Then proceed with assembly of the GREY "L" type socket on the end
of the panel cable, as follows:
01. Insert the various elements of the socket on the cable, taking
care to observe the sequence as shown in fig. 8;
18
205 mm
13 mm
128 mm
256 mm
122 mm
230 mm
208 mm
Note – For fixture, use two screws on the underside, only if the bat-
tery is to be secured in a fixed position and not removable.
13 mm
8
CAUTION! – Do not modify the electric jumper on the connector
(fig. 9).
2
9
4
02. Using a slotted screwdriver, attach the blue wire to terminal n° 1
on the connector and brown wire to the earthing terminal (4) (fig. 10).
Note – The reference numbers and symbols are printed on the con-
nector below the terminals and on the opposite side.
10
03. After fixing the two wires, insert the connector in its casing (fig.
11).
Important – The correct position of the connector is that with
the earthing symbol in the lower position.
3
1
1
4