Technical specifications
WARNINGS: • All technical specifications stated herein refer to an ambient temperature of 20°C (± 5°C) • King gates srl. reserves the right to
apply modifications to the product at any time as deemed necessary, while maintaining the same functionalities and intended use.
BATTERY BOX
Rated voltage
Maximum current
Rated battery capacity
Protection rating
Operating temperature
Complete recharging time
Dimensions
Weight
Note – The batteries in the unit are VRLA (Valve Regulated Lead Acid Batteries). They comply with the specific provision A67 of the IATA/
ICAAO regulation governing hazardous goods. Battery box is therefore not considered hazardous goods and may be transported without
any risk by air, sea and on road.
PHOTOVOLTAIC PANEL
Rated voltage
Peak power
Operating temperature
Dimensions
Weight
Warning – The glass of the photovoltaic panel has been tested to resist to hailstones and medium entity impact. In the event of particularly
consistent hail or impact, the glass may be damaged; in this case contact the King gates Technical Assistance service.
Declaration number: K110
Revision: 0
Manufacturer's name: KING GATES S.R.L.
Address: Via Malignani, 42 - 33077 - Sacile (PN) Italy
Type of product: Kit solare
Model / Type: Kit GO GREEN comprises the photovoltaic panel and the battery box
The undersigned Giorgio Zanutto in the role of Managing Director, declares under his sole responsibility, that the product specified above conforms to the provisions
of the following directives:
• Directive 2006/95/EC OF THE EUROPEAN PARLIAMENT AND COUNCIL of 12 December 2006 regarding the approximation of member state legislation
related to electrical material destined for use within specific voltage limits, according to the following harmonised standards:
EN 60335-1:2002 + A1:2004 + A11:2004 + A12:2006 + A2:2006 + A13:2008
• DIRECTIVE 2004/108/EC OF THE EUROPEAN PARLIAMENT AND COUNCIL of 15 December 2004 regarding the approximation of member state legislation
related to electromagnetic compatibility, repealing directive 89/336/EEC, according to the following standards:
EN 61000-6-2:2005, EN 61000-6-3:2007
Sacile, 10 March 2015
24 V
10 A
20 Ah
IP 44
-20 °C ÷ +50 °C (0 °C ÷ +40 °C
when charging using the back-up power supply unit connected to the mains)
approx. 15 hours (when charging using the back-up power supply unit connected to the mains)
258 mm x 235 mm x 180 mm
14 kg
24 V
30 Wp
-40 °C ÷ +85 °C
550 mm x 450 mm x 25 mm
3,5 kg
EN
- EC declaration of conformity
Declaration in accordance with the Directives: 2004/108/CE (EMC); 2006/95/CE (LVD)
Language: EN
Giorgio Zanutto
(Managing director)