Rev.0 17/05/2021
EN
Pag.40
AL 08
DEPRESSION
FUME
AL 12
EXHAUST
SYSTEM
AUGER
AL 14
PHASE
AL 15
AUGER TRIAC
CLEANER
AL 19
FAILURE
AUGER
AL 25
ALARM
Use and maintenance manual Phandheld Touch Radio
The flue is blocked.
The vacuum meter is faulty.
The fume exhaust system has a loss of
performance due to fan obstruction or voltage
drop.
No cable connection to power the gear motor
An internal part of the electronic board that
controls the pellet auger is faulty.
Possible voltage drops or incorrect input
voltage
The cleaner did not complete the movement
and is not in the correct position
Anomaly in auger geared motor operation.
Check the flue is free and clean
Check the mains voltage.
Check the mains voltage.
Check the mains voltage.
Check the flue is free and clean
Check the mains voltage.
Reset the alarm and wait for the stove to switch to
SHUTDOWN mode. Cut off and power again, the
system reactivates the cleaner searching the correct
position again.
If the problem persists, contact the Support Service
Contact the Support Service