5-1/8"
(13 cm)
35-1/2"
(90.2 cm)
1/8"
(3 mm)
Product Information
Pump on right, integral flange
Pump on left, integral flange
Fixture:*
basin area
Bathing
43" (109.2 cm) x
well
24" (71.1 cm)
water depth
To
13" (33 cm)
overflow
* Approximate measurements for comparison only.
Pump
HP
1-speed
1.25 HP
Required Electrical Service
Dedicated circuit required, protected with a Class A
Ground-Fault Circuit-Interrupter (GFCI) or Earth-Leakage
Circuit-Breaker (ELCB):
Pump/control
220-240 V, 20 A, 50/60 Hz
Locate the outlet behind the whirlpool and within 24" (61 cm)
of the pump.
1014741-1-B
K-1630
30" (76.2 cm)
59-3/4" (151.8 cm)
1" (2.5 cm)
K-1630
shown
K-1630-CK
not shown
top area
weight
52" (132.1 cm) x
115 lbs.
32" (81.3 cm)
(52.2 kg)
capacity
55 gal. (208.2 L)
Voltage
Frequency
Amperage
120 V
60 Hz
7.5 A
No change in measurements with drain
shown. (K-7161-AF or K-7161M-AF)
12-1/8"
(30.8 cm)
42-1/2"
(108 cm)
Pump/Control Access
20" (50.8 cm) W x
15" (38.1 cm) H Min.
23-1/4"
(59.1 cm)
17-1/2"
(44.5 cm)
Installation Notes
Install this product according to the installation guide.
Floor support under whirlpool must provide for a minimum of 80
lbs/square foot (390 kg/square meter) loading.
If installing a rim mount faucet, make sure there is no interference
with drain overflow and circulating system before drilling any
holes. Consult local and national codes for minimum air gap
requirements if installing a spout on the faucet deck.
Fixture conforms to ANSI Standard Z124.1. All dimensions are
nominal.
2
1-1/8"
(2.9 cm)
3/4"
(2 cm)
3/8" R.
(1 cm)
Integral Flange Detail
8"
(20.3 cm)
2-7/8" (7.3 cm)
3" (7.6 cm)
1-1/2" O.D.
3/16" R.
(5 mm)
Kohler Co.