Hold Select pressed for 2..3 sec untill Select-LED flashes. Then choose button below
Button =>
Inverter
No function
DEPT 1
level 1
DEPT 2
DEPT 3
DEPT 4
DEPT 5
DEPT 6
DEPT 7
Inverter
SELECT & SETUP
No function
DEPT 1
level 2
DEPT 2
DEPT 3
Julio 2005 / Masterlink CSCP / ES
CSCP Install level
Volt-Amp
M01
Set Low Voltage Level
Low Battery Signal
11.0 VDC / 22.0 VDC
M02
Set dischage floor
35% of C.ahr
20% .. 50%
0-10-20-30 minutes
M03
Set low battery delay time
30 sec
1..60 sec
M04
Set full charge level
80% of C.ahr
70%..90%
M05
Set minimum run time
Reset Ahr to 0000
10 min
5 min .. 90 min
M06
Set maximum run time
6 hr
1 hr .. 12 hr
M07
Exit level
Program level - advanced settings
Hold select & setup 2 to 3 sec untill both leds flashes
Volt-amp
M08
Test Low Batt. mode
on - off
M09
Change C.E.F. Manual
Exit level
Ahr-time
Charger
A01
Battery Capacity
Power Sharing Mode
200 Ah
15 Amp
40 .. 9990 ah
2-5-15-30 Amps
A02
Average Time
Consumption
Exit level
0 minutes
A03
Return Amps
1% of C.Ahr
1%..10%
A04
Float level
13.6V / 27.2V
A05
Press setup
A06
Battery type
12 /24V
A07
Exit level
Figure 7: Diagrama de ajustes nivel de instaladorl
Ahr-time
Charger
A08
Change Peukert
No function
exponent 1,27
1,01 to 1,50
A09
No function
actual read out
0.7... 0.99
A10
No function
Exit level
Figure 8: Diagrama de ajustes, ajustes avanzados
OPERATION
Set-up
C01
F01
Sleep mode
On / Off
F02
C02
Low Battery Contact
On / Off
F03
LED is switch
On / Off
F04
Exit level
Set-up
F05
Reset to factory setting
Press setup
F06
Reset all historical data
Press setup
F07
Exit level