Selecting the Sound type
Two different sounds are selectable via jumper
J15:
J15
Up and down scale modulation
k
(Default)
j
Bitone
Connections
+ Use shielded cable for the connections. One
end of the cable must be connected to Ground
on the Panel, and the other left free.
Examples A and B in the wiring diagram in Fig. 2
utilize terminal +N to activate Wave/WB or
Wave/WSB.
+ When using terminal +N to activate the de-
vice, jumper J3 must be disconnected and
terminal -A must be connected to Ground
(terminal
).
Examples A and B in the wiring diagram in Fig. 3
utilize terminal –A to activate Wave/WB or
Wave/WSB.
+ When using terminal –A to activate the de-
vice, jumper J3 must be connected.

TERMINAL DESCRIPTION

Tamper: terminals AS will close when the
AS
Tamper Switch 8 closes; and will open
when the T amper Switch 8 opens.
Power (Wave/WB and WSB):
13.8 V_; 25 mA Max.
Control Input (Wave/W and WS):
+B
The device will hold Standby status while
T erminal +B is open (floating). The device
will activate when terminal +B connects to
the Positive Voltage (13.8 V).
Control Inputs (Wave/WB and WSB):
The device will hold standby status while
terminal +N is connected to the Positive
+N
Voltage (13.8 V) and termi nal –A is
–A
connected to Ground; the device will
activate when either terminal +N or –A
opens (floating).
M Ground
M
M
M
SOUND TYPE
When connecting either Wave/W or Wave/WS
refer to Examples A and B in the wiring diagram in
Fig. 4.
+ Examples A and B in the Wiring diagrams
show the connection of Wave Series devices
to two different types of Panel terminal
boards.
The acronyms that identify the terminals in the
wiring diagrams (Figures 2, 3 and 4) are valid for
Custom Panels only, therefore, when connecting
the device to Non-Custom Panels consider that:
terminal +B supplies a 13.8 V Direct Current;
terminal +N supplies the Positive Voltage
(13.8 V) during Panel Standby status,
whereas it is open (floating) during Alarm sta-
tus;
terminal NC is closed to terminal COM during
Panel Standby status, whereas it is open
(floating) during Alarm status;
terminal NO is open (floating) during Panel
Standby status, whereas it is closed to Ter-
minal COM during Alarm status;
terminal OC is closed to Ground (terminal -
during Panel Standby status, whereas it is
open (floating) during Alarm status;
terminal +A supplies the Positive Voltage
(13.8 V) during Panel Alarm status, whereas
it is open (floating) during Standby status.
If Tamper detection is required: connect terminals
AS in series to the Panel tamper line.

TECHNICAL SPECIFICATIONS

Operating Voltage
Current draw (+B):
Wave/WB and Wave/WSB
Wave/W
Wave/WS
Battery (art. CB7203)
Sound output
Candela
Protection Rating
Operating T emperature Range
Dimensions (LxHxP)
Weight
-
- )
-
-
13.8 V_
25 mA Max.
90 mA
225 mA
1/3AA 300 mAh 7.2 V
104 ±3 dB at 1 m
60 cd
IP31
5 °C to 40 °C
126x132x53 mm
310 g Max.