SMP301-07
5.1
Connections and displays
No. in
Element
fig. 1, page 2
1
AC plug
2
LED LD6B "battery charging status"
3
LED LD6 "battery fuse defective"
4
2x flat plug P6 for positive terminal battery
5
Battery fuse F6 (20 A type ATO)
6
Plug-in fuse F1 for output group 1 (maximum 15 A)
7
Plug-in fuse F2 for output group 2 (maximum 15 A)
8
Plug-in fuse F3 for output group 3 (maximum 15 A)
9
Plug-in fuse F4 for output group 4 (maximum 15 A)
10
Plug-in fuse F5 for output group 5 (maximum 15 A)
11
3x flat plug P5 6.3 mm for group 5
12
3x flat plug P4 6.3 mm for group 4
13
Flat plug P3 6.3 mm for group 3
14
Flat plug P2 6.3 mm for group 2
15
Flat plug P1 6.3 mm for group 1
16
5x LED "plug-in fuse F1 – F5 defective" (LD1 – LD5)
17
10x flat plug P7 6.3 mm battery terminal / common earth connection
The LED LD6B indicates the battery charging status as follows:
• Main charge (12.7 V):
flashes yellow slowly (1 second on, 1 second off)
• Equalising charge (approx. 14.4 V):
flashes yellow quickly (0.5 seconds on, 0.5 seconds off)
• Charging process complete:
lights up yellow
• Fault:
flashes yellow very quickly