the supplier's instructions. QuickNet can be fixed, if required, to the
subfloor by means of glue or staples. Fixing with staples is only allowed
in the net, and never over the heating cable. Any metal shield, braid,
screen or equivalent electrically conductive covering of the QuickNet
shall be connected to an earthing terminal.
WOODEN TOP FLOORS
QuickNet-N (90W/m²) can be installed under engineered wooden floors
(laminate) and parquet floors under certain conditions.
For wooden floors QuickNet-N should be embedded in a layer of
concrete of 15-30mm. The thermostat that controls the QuickNet should
be regulated by a floor sensor (or by room sensor with floor limiter). The
floor sensor limit should be set to 27°C as maximum temperature. The
type of wood should be compatible with underfloor heating.
There shall be no thermal barrier on top of the floor (like carpet or furniture).
QuickNet-P (160W/m²) shall in no case be installed under wooden floors.
END OF LIFE DISPOSAL
The thermostat must be disposed of as Waste Electrical and Electronic
Equipment (WEEE directive) according to local regulations. The rest of
the heating cable system must be disposed of as construction waste.
8 | nVent.com/RAYCHEM