CLASSIFICATION AND TYPE.

GENERAL CHARACTERISTICS

Internal pressure transducer.
minimum level detector. For its connection see Fig.5a for VSD 6 M/T and 10 M/T or Fig.5b VSD 9 T/T and 14 T/T.
14

TECHNICAL SPECIFICATIONS

TYPE
VSD 6 M/T
VSD 10 M/T
Input voltage
1~230Vca+-20%
1~230Vca+-20%
Frequency
Max current per phase
6A (3~230V)
10A (3~230V)
Inrush current
20% per 10s
20% per 10s
Maximum operating
+16bar
+16bar
pressure
Adjustable pressure
0,5-12bar
0,5-12bar
Protection
IP55
IP55
Max water temperature
40°C
40°C
Max ambient temperature
0-50°C
0-50°C
Fuse
10A
20A
T
and cannot be used with other liquids.
CHAPTER 3
It is essential to install a check valve or foot valve on the suction side of the pump in case of positive suction head installation.
the pump resulting in having to repeat the subsequent pump priming procedure.
CHAPTER 4

ELECTRICAL CONNECTION

WARNINGS:
prevent possible electric shock.
device
Electrical connection must be performed according to the local regulations in force.
The electrical conductors must in particular be protected from high temperatures, vibrations and bumps that could cause
mechanical or chemical damage.
(30mA class A or AC) and secured with a 16A circuit breaker for VSD 6 M/T and 10 M/T and 20A for VSD 9 T/T and 14 T/T
standard requirements in force.
EN
VSD 9 T/T
VSD 14 T/T
3~400Vca
3~400Vca
9A
14A
20% per 10s
20% per 10s
16bar
16bar
0,5-12bar
0,5-12bar
IP55
IP55
40°C
40°C
0-50°C
0-50°C
pump 16A
25A
general 20A
15