Function:
Start command for hygiene flushing
☞
This is triggered with a pulse.
• Only for fittings that have this corresponding function backed up within the program
ID and which have a flow duration set.
• In such fittings the hygiene flushing process is performed 1x.
Pin:
Signal:
Input 3
IN3
Function:
Start command for cleaning circuit.
☞
This is triggered with a pulse.
• Fittings within the network are brought on-line to the cleaning mode. Fittings can not
be triggered.
Stop command for switching off cleaning
☞
With further pulse
Cleaning switch-off is automatically terminated after 10 min.
Pin:
Signal:
Input 4
IN4
Function:
Zone switching
e.g. for: summer/winter mode, day/night mode or room occupied/not occupied.
☞
The input can be connected with a switch, time switch or GLT contact.
• Functionality depends on the contents of the program ID within the electronic
module.
Pin:
Signal:
GND
IN GND
Function:
Reference for IN1 through IN4
e.g. for: summer/winter mode, day/night mode or room occupied/not occupied.
Pin:
Signal:
OUTPUT1
OUT1
8
Level at
Max. line length:
function:
LOW
3 m
Level with
Max. line length:
function:
HIGH zone A
3 m
LOW zone B
Level:
Max. line length:
Reference
3 m
Level:
Max. line length:
4 V DC
3 m
Current
10 mA