Function:
LED driver output (constant-current output approx. 10 mA)
Is assigned to thermal disinfection
Normal functionality: Permanently "ON" for the duration of the thermal disinfection
process
• Fault in thermal disinfection: Fast pulses (f ? 5 Hz)
• Completion of thermal disinfection: Slow pulses (f ? 2 Hz)
• Acknowledgement see IN1
Pin:
Signal:
OUTPUT2
OUT2
Function:
LED driver output (constant-current output approx. 10 mA)
Serves to indicate general faults
Functionality for fittings and/or collective fault message for functionalities:
Permanently "ON"
• Fault in UPS: Slow pulses
• Acknowledgement with Power ON (OFF/ON) by the ECC function controller, or
automatically after 0.5 h.
Pin:
Signal:
GND
OUT GND
Function:
Reference for OUT1 and OUT2

10. Assembly Instructions

When installing several devices, to ensure an unimpeded flow of cooling air, it is
important to provide a minimum distance of 15 mm to neighbouring parts.
Mounting on and dismounting from top-hat rails TS 35
10.1 For mounting, insert the device with the top-hat rail guide into the lower edge of the
top-hat rail and tilt it upwards to make it lock in position.
10.2 To dismount, lift the device in order to overcome the spring force, and then tilt it down
to unlock it.
Installing on a wall
10.3 Mark the holes for the 4 screws.
10.4 Drill according to the markings.
Level:
Max. line length:
4 V DC
3 m
Level:
Max. line length:
Reference
3 m
Current
10 mA