Troubleshooting - Luminance Brands Kathy Ireland Home HF1161BQ00 El Manual Del Propietario

Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

FOR YOUR OWN SAFETY TURN OFF POWER AT FUSE BOX OR CIRCUIT BREAKER BEFORE
TROUBLESHOOTING YOUR FAN.
TROUBLE
1. Fan will not start. 1. Fuse or Circuit Breaker blown.
2. Loose Power Line Connections to the Fan
or Loose Switch Wire Connection in the
the Switch Housing.
2. Fan sounds
1. Blades not attached to Fan.
noisy.
2. Screws securing Fan Blades to Motor Hub
are loose.
3. Loose Screws in Motor Housing.
3. Fan wobbles
1. Set Screws in Motor Coupler are loose.
excessively.
2. Set Screw in the Hanger Ball/Downrod
Assembly is loose.
3. Hanger Bracket and/or Ceiling Outlet Box
is not securely fastened.
4. Fan Blades out of balance.

13. Troubleshooting

!
PROBABLE CAUSE
WARNING
SUGGESTED REMEDY
1. Check Main and Branch Circuit Fuses or Circuit Breakers.
Make sure main power is turned OFF.
2. Check Line Power Connections to Fan and Switch Wire
Connection in the Switch Housing.
1. Attach Blades to Fan before operating.
2. Check to make sure the Screws which attach the Blades
to the Motor are tight.
Make sure main power is turned OFF.
3. Check to make sure all Screws in Motor Housing are.
snug (Not Over-Tight).
1. Tighten Set Screws securely in the Motor Coupler.
2. Tighten the Set Screw in the Hanger Ball/Downrod
Assembly.
3. Tighten the Hanger Bracket Screws to the Outlet Box,
and/or secure Outlet Box.
4. Interchanging an adjacent (side by-side) Blade pair can
redistribute the weight and result in smoother operation.
24
WARNING
!
WARNING
!
ETL Model No.: HF1161

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Kathy ireland home hf1161ms00Kathy ireland home hf1161sw00

Tabla de contenido