INTRODUCTION
Card Reader
The CAPXL / CAPXLV is designed specifi cally for the LMMC-
MINI reader to be mounted on the faceplate.
1. Disconnect power from the CAPXL / CAPXLV.
2. Remove and discard the wing nuts and reader cover from
the CAPXL / CAPXLV.
3. Install the reader and secure with the screws.
4. Apply silicon around the cable hole.
5. The reader can be wired to any of the 4 Wiegand Inputs
on the door control boards. Insulate any unused wires
from the CAPXL / CAPXLV to prevent a short. (Refer
to instructions provided with your reader for more
information.)
6. Reconnect power to the CAPXL / CAPXLV.
7. Refer to myQ
®
Business™ for programming.
PRE-INSTALL
INSTALL
Reader
Cover
Reader
ON
WIEGAND
INPUT
21
NETWORK
ACCESS CONTROL
Mounting Plate
Use 18-24 AWG
Reader is wired to WIEGAND INPUT
NOTE: The length of the unshielded
reader wires should be kept to
a minimum to avoid electrical noise.
Wing Nuts
Mounting
Holes
Cable
Mounting Plate
Hole