Troubleshooting Continued
Symptoms
9. Whirlpool jets run,
but River Jets do
not operate as
not operate as
described.
described.
10. Volume control
arrows do not
arrows do not
change water flow
as described.
as described.
11. Air flow through
jets does not start or
jets does not start or
stop when
Tidewater" control
Tidewater" control
button is pressed.
12. Air continues to
flow through one or
more jets for several
seconds after
Tidewater" control
button is pressed.
Kohler Co.
Probable Causes
A. Insufficient water in whirlpool basin.
B. Control switch does not work.
C. Butterfly valve does not work.
D. Auxiliary control does not work.
A. Control switch does not work.
B. Variable flow valve does not work.
C. Pump circuit board does not work.
A. Control switch does not work.
B. Butterfly valve does not work.
C. Auxiliary control does not work.
A. Normal operation air will stop
flowing in a short time.
Recommended Action
A. Fill whirlpool so water covers
water level sensors.
B. Check wiring. Replace control switch.
C. Check wiring. Replace butterfly valve.
D. Check wiring. Replace auxiliary control.
A. Check wiring. Replace control switch.
B. Check wiring. Replace variable flow
valve.
C. Check wiring. Replace pump circuit
board.
A. Check wiring. Replace control switch.
B. Check wiring. Replace butterfly valve.
C. Check wiring. Replace auxiliary control.
A. No action required.