STEP 13.
TESTING
Determine that the pilot is igniting and burning properly and that main
burner ignition is satisfactory by turning the thermostat off and back on.
Make this determination with the appliance burner both cold and hot.
Perform this step as many times as is necessary to satisfy yourself that
the automatic intermittent pilot system is operating properly.
- Sequence the appliance through at least three (3)
operating cycles.
- Check all furnace connections for gas leaks with leak
detector solution, including plug installed into valve body.
Do not use open flame.
STEP 14.
Temporarily disconnect the
wiring harness (57), orange ignitor
wire (33) and the black flame
sensor wire (47).
Also, disconnect the red
and black wires connecting
the Battery Pack (49) and the
Wiring Harness (57).
INSTALLATION
57
47
49
Page 22
33
57
Red
Wire
Red
Wire
Black Wire
Black
Wire
1019068-C