TROUBLESHOOTING
FAULT PHENOMENON
UNABLE TO START
SWITCH, PRODUCT
FAILS TO WORK.
ELECTRIC MOTOR
SMELLS BAD FIRST
FEW TIMES OF USE.
STOPS WHILE
USING.
TOO MUCH
PULP IN THE JUICE
ABNORMAL
VIBRATION OR
LOUD NOISE.
LOW QUANTITY OF
JUICE
FILTER BASKET
STUCK
11
CAUSE ANALYSIS
1. POWER PLUG NOT PLUGGED IN
2. HEAD COVER INSTALLED
INCORRECTLY
IT IS NORMAL.
1. LOW POWER VOLTAGE IS OFF
2. EXCESSIVE INGREDIENTS
3. PUSHING PUSHER WITH EXCESSIVE
FORCE
4. MOTOR OVERHEAT CONTROL
PROTECTION
1. JUICE EXTRACTION SCREEN IS
DAMAGED.
2. TOO MUCH PULP IN THE CENTRAL
RING.
1. IMPROPER INSTALLATION OF JUICE
EXTRACTION SCREEN OR
IN BALANCED INSTALLATION.
2. UNSTABLE PLACEMENT OF
PRODUCT OR CAME OFF OF
FOOT PAD.
3. EXCESSIVE INGREDIENTS
1. TO MUCH PULP IN FILTER BASKET
2. PUSHING PUSHER WITH EXCESSIVE
FORCE
PRODUCE OR PULP IS STUCK. THIS
MAY HAPPEN WITH CELERY STRINGS.
CAUSE ANALYSIS
1. INSERT THE POWER PLUG AGAIN;
2. INSTALL HEADCOVER IN PLACE
PLEASE CALL CUSTOMER SERVICE IF
THE PRODUCT CONTINUES TO HAVE
AN ODOR
1. CHECK IF POWER IS OFF
2. DISCONNECT POWER, TAKE OUT
THE SURPLUS INGREDIENTS.
3. PUSH THE ROD GENTLY.
4. RESTART IT AFTER STOPPING
20-30 MINUTES.
1. REPLACE THE SCREEN.
2. CLEAN THE CENTRAL RING.
1. INSTALL JUICE EXTRACTION
SCREEN IN PROPER PLACE.
2. PLACE PRODUCT STABLY OR
INSTALL THE FOOT PAD IN
PROPER PLACE.
3. DISCONNECT POWER AND TAKE
OUT EXCESSIVE INGREDIENTS.
1. CLEAN CENTRAL RING.
2. PRESS THE PUSH ROD WITH LESS
FORCE.
DISCONNECT POWER, REMOVE FOOD.