Commissioning
Connecting the device
When you plug in the device, the readiness for operation is signalled visually (lights
turning on).
Caution: Do not plug or unplug the device with wet hands.
Power
The power switch is used to turn the unit "on" and "off".
By default, the device is set on manual mode and the fan speed on level 1.
Speed
Press the Speed button to control the fan speed from 1 to 3 when it is under manual
mode. The current fan level is visible on the display.
Mode
1.
Manual mode
Adjust the fan speed manually.
2. Automatic mode
The device automatically adjusts the fan speed from lowest to highest mode
depending on the quality of the air.
3. Sleep mode
In the Sleep mode, the device operates at the lowest fan speed for minimal noise
disturbance. Apart from the Sleep display, all other displays turn off.
4. Timer (available via the App control)
With the timer you can set the running time of the device. Times between 1 and 9
hours can be selected.
Sterilize
Press the button to turn on/off the UV-GI sterilization light.
Filter reset
When turning on the device for the first time you have to renew the filter life indicator.
Press both the On/Off and Speed button for 5 seconds. The filter replacement reminder
icon is not blinking anymore which means that the filter life indicator is renewed.
7