Commissioning
Connecting the device
When you plug in the device, the readiness for operation is signalled
acoustically.
Caution: Do not plug or unplug the device with wet hands.
Power
The power switch is used to turn the unit "on" and "off".
Auto
In the automatic mode, the fan speed of the device is controlled via the air
quality sensor. The device automatically adjusts the fan speed from lowest to
highest mode depending on the quality of the air.
The current air quality is shown in both quantitative and qualitative ways on the
display.
Air quality
Good
Medium
Bad
Timer
With the timer you can set the running time of the device. Times between 1 and
8 hours can be selected.
Ioniser/UVGI
Press the button to turn on/off the ioniser function as well as the UVGI
sterilisation light when the device is operating in Normal or Auto mode.
Filter reset
When turning on the device for the first time, and every time a filter change is
made, you should renew the filter life indicator.
Press both the Ioniser and Timer button for 3 seconds.
The filter life indicator is renewed and shows 100%.
Sleep
In the Sleep mode, the device operates at the lowest fan speed for a minimal
noise disturbance. Apart from the Sleep display, all other displays turn off.
To exit the Sleep mode, press either Sleep or Speed button.
PM
(μg/m
)
3
2.5
10 – 60
61 – 150
151 - 300
Display
Green light
Orange light
Red light
Fan stage
1
2
3
8