4 - PROGRAMMING

4.1 Description of the programming buttons

Buttons
Function
- Triggering of auto-programming
B
- Memorising/clearing the remote controls
- Modifying a parameter value
- Use of forced operating mode
A
- Selecting a parameter
Warning
- Parameter warning light selected
light A
Warning
- Parameter value warning light
light B
- Fault indicator warning light

4.2 Auto-programming - Fig. 15

[1]. Control the motor with button "A" so that the transmission shuttle is
engaged on the carriage and bring the door to the closed position:
- Keep pressing button "A" to cause the shuttle to move.
- Release the button to stop the movement.
- Press button "A" again to trigger movement in the opposite direction.
Release button "A" before forcing the motor on the door.
[2]. Adjust the closed position using button "A".
Release button "A" before forcing the motor on the door.
[3]. Press "B" to launch the auto-programming cycle.
The door performs a complete Opening-Closing cycle.
- If the auto-programming is correct, warning light B goes out.
- If the auto-programming cycle was not successful, warning light B
continues to flash (2 flashes).
During auto-programming:
- If the door is moving, the movement is stopped and auto-programming
is interrupted if any of the buttons are pressed.
It is possible to access auto-programming mode at any moment including when
the auto-programming cycle has already been completed.
Note: The remote controls supplied in the kit have already been
memorised.
At the end of installation, it must be checked that the obstacle detection
complies with annex A of the standard EN 12 453.
4.3 Locking access to the parameters (button A) -
FIG. 16
Press button A repeatedly until the indicator light A flashes 4 times.
Press button B once:
- The parameters menu (button A) is locked.
Once installation is complete, the parameters menu must always be
locked to ensure the safety of users.
Non-observance of this instruction can result in serious injury to
persons, e.g. when trapped by a door.
At this stage of the installation, the GM600 motorisation is ready
to operate.
5
Warning light legend:
off
flashing
WARNING
WARNING

5 - OPERATING TEST

5.1 Using the remote controls - Fig. 17

5.2 Obstacle detection operation - Fig. 18 and 19

When an obstacle is detected during closing, the door re-opens (Fig. 18).
When an obstacle is detected during opening, the door will stop (Fig. 19).
Check that the obstacle detection function works when the door encounters a
50 mm high obstacle on the ground.

5.3 Integrated lighting operation

The lighting comes on each time the motorisation is switched on. When the
door stops moving, it goes off automatically after 30 seconds.
Repetitive use will cause the light to be lit constantly which may result in the
light being switched off automatically due to thermal protection.

5.4 End-users training

The end-users must be imperatively instruct to the safety use of this motorised
door (standard use and manual release principle) as well as to periodic and
compulsery checks.

6 - CONNECTING ADDITIONAL DEVICES

6.1 Description of the various additional devices -
Fig. 20
No.
Description
1
Orange light
3
Key lock
4
Aerial
5
Battery
6
Photoelectric cells
6.2 Electrically connecting additional devices - Fig. 20
to 21
Switch off the electrical supply to the motor before performing any operation on
the additional devices.
General electrical diagram (Fig. 20)
Photoelectric cells (Fig. 21)
When positioning the cells, remove the bridge created between terminals 1
and 2.
If cells are removed, it is essential to recreate the bridge between
terminals 1 and 2.
7 - PARAMETER SETTING AND
OPERATING OPTIONS

7.1 General parameter-setting diagram - Fig.22

7.2 Meaning of different parameters

Programming example: Adjusting the long slow zone (Fig. 23)
Warning light A
Obstacle detection sensitivity
Warning light B 1
: very low sensitivity
2
: slightly sensitive
3
: standard
4
Comments
If this parameter is modified, the installer must check that
the limitation of forces complies with appendix A of the
standard EN 12 453.
: very sensitive
Copyright © 2015 Simu SAS. All rights reserved