Specific Operation; Clearing The Remote Controls And All Settings; Clearing The Remote Controls - Fig; Reinitialising All Settings - Fig - Simu GM600 Manual De Instalación

Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 38
GM600
If this parameter is modified, the installer must check that the obstacle
detection complies with annex A of the standard EN 12 453.
Non-observance of this instruction can result in serious injury to
persons, e.g. when trapped by a door.
Warning light A
Coupling speed when closing
Warning light B 1
: no reduction in speed
2
: short reduction in speed
3
: long reduction in speed
Comments
1 : No reduction in speed at the end of closing.
2 : The speed is reduced during the last 30 centimetres.
3 : The speed is reduced during the last 50 centimetres.
If this parameter is modified, the installer must check that the obstacle
detection complies with annex A of the standard EN 12 453.
Non-observance of this instruction can result in serious injury to
persons, e.g. when trapped by a door.
Warning light A
Auto-programming mode
Warning light B 2
: waiting for auto-programming
0
: self-learning is complete
Warning light A
Warning light B 0
: the parameters menu is locked
If button B is pressed, move on to step 10 to unlock the parameters
menu
Warning light A
Warning light B 1
: Power supply
2
: Solar
Memorising the remote controls for operation in «Total opening»
mode (Fig. 24)
The remote controls supplied in the kit have already been memorised.
It is possible to memorise up to 32 control channels.
If this procedure is carried out using a channel which has already been
memorised, this channel will be cleared.
Memorising a Color type remote control or similar (Fig. 25)

8 - SPECIFIC OPERATION

See the user booklet.
9 - CLEARING THE REMOTE CONTROLS
AND ALL SETTINGS

9.1 Clearing the remote controls - Fig. 26

Press button "B" until the light flashes (7 secs).
Causes all memorised remote controls to be cleared.

9.2 Reinitialising all settings - Fig. 27

[1]. Press button "A" 3 times to access the auto-programming parameter.
[2]. Press button "B" to enter auto-programming mode. Warning light B
flashes twice continuously.
[3]. Control the motor with button "A" so that the transmission shuttle is
engaged on the carriage and brings the door to the closed position.
Copyright © 2015 Simu SAS. All rights reserved
WARNING
WARNING
Locking the parameters menu
Power supply type
[4]. Press "B" to launch the auto-programming cycle.
The door performs a complete Opening-Closing cycle.
- If the auto-programming is correct, warning light B goes out.
- If the auto-programming cycle was not successful, warning light B
flashes twice continuously.
10 - UNLOCKING THE PARAMETERS MENU
- FIG. 28
Note: If the parameters menu is locked and no memorised remote control
is available, it will be necessary to memorise a remote control first (fig.
24 or fig. 25).
[1]. Press and hold button A on the GM600.
[2]. Without releasing button A, press a button on a remote control which is
already memorised. The light on the GM600 comes on briefly to indicate
that unlocking has taken place.
[3]. Release button A.
Once the work being carried out by the professional is complete, the
parameters menu must always be locked to ensure the safety of users.
Non-observance of this instruction can result in serious injury to
persons, e.g. when trapped by a door.

11 - REFITTING THE COVER FLAP - FIG. 29

Fit the cover flap.

12 - DIAGNOSTICS

Warning light B
Meaning
Motor waiting for auto-
2
programming
Cell fault
3
Motor thermal
5
protection device
Motor current
6
measuring circuit fault
or sensor fault
Maximum power
7
delivered by the motor
reached during the
auto-programming
phase
WARNING
Solution?
Start auto-programming
Check that no obstacles
prevent the cells from
detecting.
Check the wiring of the cells
or create a bridge between
terminals 1 and 2 if no cells
are installed.
Check the correct alignment of
the cells.
Leave the motor to cool until
the fault disappears.
Switch off the power supply
(mains and backup battery),
wait a few minutes then
reconnect the power supply.
Perform an auto-programming
cycle. If the fault remains,
contact Simu technical
assistance.
Product has reached
operating limit.
6

Publicidad

Tabla de contenido
loading

Tabla de contenido