GENERAL FEATURES
Outdoor self-powered sirens for security systems:
•
City LED Plus with small white ABS container
•
City X LED Plus with small STAINLESS Steel ABS container
City CARBON LED Plus with small ABS container with carbon look
•
•
TS85 P LED Plus with white ABS container
•
TS85 V LED Plus with white varnished Galvanized iron container
•
TS85 X LED Plus in AISI 304 STAINLESS Steel container
-
The TS85 P/V/X LED Plus models internally have an independent fastening cover that creates a second obstacle
to possible tampering.
-
The unified ant-removal system found on all models enables to simultaneously protect against the removal from the
wall and the opening of the cover and further simplifies assembly operations.
E
N
Initial blockage
G
Emergency timer
Type of sound modulation
Alarms Count
FLASH mode
Siren control input (STC)
Control input (LED)
Block (B) Input
FAILURE (FAULT) output
TAMPER (T T) output
Battery polarity inversion
Current limiter
Autotest
Level indicator
AUTOTEST
All models have an autotest system for the following components:
•
LED test: performed periodically.
•
Cone management Circuit test: performed exclusively with siren in alarm state and integrated cone
•
Cone test: performed exclusively with idled siren
•
Battery "dynamic" test: within 15 minutes from the first power supply or at the exit of the programming and, subsequently, at intervals
of approximately 24 hours, the LEDS and the Flash are activated simultaneously to verify the correct functioning of the battery.
•
Battery "static" test: a check of the tension value at the ends of the battery is performed periodically by disconnecting the charge
coming from the control unit.
Once all connections and programming are completed and the siren is closed, perform a test of the alarm to test correct
functioning.
The power supply must come from a very low voltage security circuit with the features of a limited power source protected
by a fuse.
GENERAL FEATURES
• The battery can be connected in the absence of power from the control unit,
program and close the cover without activating the Cone. The siren does not
sound until the power supply terminals (+/-) and the control terminal (+SA)
are not connected to the control unit.
• If the device that controls the siren is broken, a programmable emergency
timer blocks it
• It is possible to select from one of the 8 different tones
• If programmed, it counts a maximum of 5 alarms in 24 hours
• If the SA input is unbalanced, it flashes for 40 minutes
• If the SA input is unbalanced, it flashes until the STC input is rebalanced
• If the SA input is unbalanced, it flashes until the SA input is rebalanced
• Programmable
• Programmable
• Blocking of the sound in the presence of a positive
• Microprocessor block
• Low level or missing battery
• Flash fault
• LED fault
• Cone fault
• Cone management circuit fault
• Siren and/or cover anti-removal
• Anti-vibration
• Overheating
• Anti-foam (optional S85 mode)
• The siren is protected against accidental battery polarity inversion
•
All models have a current limiter to avoid the siren from overloading the control
unit.
• FLASH, LED, Cone, Cone management Circuit, Battery periodic check
• A bubble, inserted inside the container, enables correct installation
- 10 -