Technical Features - AVS Electronics LED Plus Serie Manual General De Instalación

Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

Technical Features

Power supply
Minimum operating voltage
Low voltage threshold
Rated supply voltage
Max. consumption in charging from CP
Consumption in alarm from CP
Quiescent current
Sound pressure level dB (A) at 3 meters
Siren frequency HZ
Allocable battery
Degree of protection
Operating temperature
Container size (DXLXH) in mm
Weight in Kg
Performance level EN50131 - 4
Certification body
Board
T AMP E R
J 4
TAMPER
RELAY
T
TAMPER output with positive safety, with Contact Normally Closed, capacity 3 A - 24 V = Is
T
activated by the Anti-removal (Anti-opening and Anti-tearing) system connected to connector
J4, the Lack of Power supply from the control unit and from the Anti-foam, Anti-perforation and
Over temperature probes. The relay remains in alarm status as long as the cause generating
the activation persists. The Anti-foam, Anti-perforation and the Over temperature signals can be
deactivated through programming.
For the configuration refer to the FUNCTIONS TABLE.
B
Block Input. With positive present, the sound of the Cone is inhibited.
FA
Fault signalling output. It provides a transistorized negative, max. 50 mA, which is lost in the case
of malfunctioning of the Cone, Cone handling circuit, Flash, LEDs. In the case of the Siren battery
is Low or Faulty. Loss of remote power source, loss integrity of trigger command interconnection.
LED
Supplementary control input.
For the configuration refer to the FUNCTIONS TABLE.
+SA / DB
ALARM Input. When this input is unbalanced, the Cone and the Flash is activated.
For the configuration refer to the FUNCTIONS TABLE.
STC / DA
CONTROL UNIT STATUS Input.
For the configuration refer to the FUNCTIONS TABLE.
-
Negative power supply
+
Power Positive and Siren Battery Recharge. 13.8 V power supply =
S1
Not used
J1
Cone and Siren Battery connection connector
J2 - LED
LED and FLASH connection connector
J3 - FOAM
Optional Anti-foam connection connector - S85 mode
J4 - TAMPER
Anti-removal system connection connector
PB1
Programming button
PB2
Programming button
CITY (X) LED Plus
CITY CARB.LEDPlus
9,5V (battery charging not warrantied – not compliant with EN50131 requirements)
12,8V (for correct battery charging - compliant with EN50131 requirements)
80 x 200 x 250
1.3
S T C
+S A
T
T
B
F A
LE D
DA
DB
S 1
TS85 P LED Plus
9.6 V = / 15 V =
10.5 V =
13.8 V =
400 mA
100 mA
40 mA
105 dB (A) - Depending on modulation
between 1300 and 1750
12V - 2.3 Ah
IP34
between - 25°C and + 55°C
110 x 235 x 290
2.0
GRADE 3 CLASS IV
Telefication
F OAM
J 1
- 11 -
TS85 V LED Plus
TS85 X LED Plus
110 x 235 x 290
2.1
J 3
J 2 LE D
E
N
G

Publicidad

Tabla de contenido
loading

Tabla de contenido