FOR YOUR SAFETY
Failure to observe cautions and follow instructions for
use and maintenance can cause tank, hose or other
parts to become corroded, weakened, and/or burst.
This can result in serious injury or property damage
from forcible ejection of parts or high-pressure
discharge of spray material. Do not use any flammables
or boiling liquids in this sprayer as it is not designed nor
intended for such use. Some spray materials can ignite
or explode. Do not spray in an enclosed space, near an
open flame such as found in a bbq grill or water heater,
near an electric motor or open switch, or any source of
heat. Do not smoke while spraying. Use of flammables
could result in serious injury or property damage from
unintended ignition or explosion. Do not use any
caustics or acids, bleach, or acetone in this sprayer,
since these can damage or weaken the sprayer and its
parts, resulting in serious injury or property damage.
Keep out of reach from children and pets. Always read
and follow directions on the spray material container,
including the need for protective clothing. Before
using your sprayer, thoroughly inspect both inside and
outside of the sprayer and if tank, hose or other parts
appear to be damaged, discolored, brittle, excessively
soft or loose. Do not pressurize with any mechanical
device such as an air compressor, since this can create
dangerous pressure and bursting of parts and result in
serious injury. Wear long-sleeved shirt, pants, gloves,
goggles or similar protective clothing when spraying.
PROP 65 WARNING: This product can expose you to
one or more chemicals, including lead, known to the
State of California to cause cancer and birth defects or
other reproductive harm. Wash hands after handling.
For more information go to
www.p65warnings.ca.gov.
LIMITED WARRANTY
H. D. Hudson Manufacturing Company warrants to
the original consumer purchaser of this product at
retail that it is free from problems in materials and
workmanship for the period of 90 days from the
original date of purchase. This warranty does not apply
to damage to the product resulting from accident,
misuse, neglect, alteration, modification, tampering, or
failure to follow instructions supplied with the product.
This warranty does not cover normal wear and tear
of o-rings or seals, and the warranty shall be void if
the product is used commercially. If the product or
any part of it should malfunction within the warranty
period, call 1-800-977-7293. Valid only in North
America.You must retain your sales receipt as proof of
the date of purchase and include it with any return of
the product.
871-035 Instruction
99598 & 99599 FOG® Electric Atomizers
If you have any questions or concerns, or missing parts, Do not return sprayer to the store!
Call our hotline: 1-800-9-SPRAYER (1-800-977-7293)
Common maintenance questions: www.hdhudson.com/FAQS
H. D. HUDSON MANUFACTURING COMPANY EXCLUDES
LIABLITY UNDER THIS WARRANTY FOR ANY AND ALL
INCIDENTAL AND CONSEQUENTIAL LOSS OR DAMAGES.
DO NOT operate this sprayer in small, enclosed areas,
or any where any spray or foreign material could
be sucked into the air intake. DO NOT overheat the
motor. Be sure air intake is kept open at all times.
DO NOT use this sprayer for paint spraying. DO NOT
spray gasoline or other flammables. DO NOT alter the
sprayer. DO NOT store checmicals in canister. ALWAYS
READ AND FOLLOW instructions for chemicals to be
applied. IF SPRAY PATTERN BECOMES IRREGULAR,
turn sprayer off, remove the intake strainer and clean
the screen. IF CORD BECOMES DAMAGED, it must
be replaced before further use. DO clean sprayer
thoroughly after each use.
SPECIAL NOTICE TO USERS
Damage in transit, wearing of nozzles or other parts,
temperature, altitude, climatic factors and manners
of use may effect the performance of this equipment.
Careful maintenance, approved calibration procedures
and repeated testing of output are necessary for
safe and satisfactory results. Users must determine
that the rate of application is proper for the chemical
being used and the conditions under which it is being
applied.
99599 OPERATION
Fill the canister with the desired amount of spray
material. Reposition the sprayer on canister top and
snap clamp so it fits tightly. Check the switch to make
sure it is "off" before plugging into a 110/120 volt
AC outlet. Once operating, the discharge rate of the
sprayer may be adjusted by turning the discharge
control.
Spray Adjustment: The 99599 has an adjustment
range of 1.5 to 5.3 gallons/hr. Spray direction is variable
through all degrees between 35 upward
to 35 downward.
Wettable Powders: The 99599 sprays wettable
powders at a maximum discharge rate of
5.3 gallons/hr. Preliminary testing is recommended to
insure that desired rate is obtainable. Shake or agitate
solution periodically to keep powders in suspension.
Spray Patterns: The 99599 atomizes 95% of its output
of less than 50 microns. Average particle size is
20 microns.
After Use: To store the 99599 or change spray
materials, detach the sprayer from the canister and turn
99598
it "on" to flush out any spray material. After use with
wettable powders, detach the canister, immerse the
supply tube in clear water and flush until no residue
can be seen in the supply tube. Wash the canister
thoroughly. Sprayer should be cleaned out after
each use.
99598 OPERATION
Fill the canister with the desired amount of spray
material. Reposition the sprayer on the canister
top and snap clamp so it fits tightly. Check the
spray selector valve on the tube that extends from
the motor housing to the tank cover plate and set
it according to the desired spray pattern. "Heavy"
setting is achieved with valve lever turned full left to
closed position. This covers the valve opening and
pressurizes the canister. "Heavy" setting produces a
dense wetting spray, ideal for application of residual
or surface type spraying. "Fine" setting is achieved
by turning valve lever full right to open position. This
opens the valve and allows air not utilized in spray
discharge to escape. "Fine" setting produces ultra
fine particles, ideal for flying insect control. Check the
switch to make sure it is "off" before plugging into a
110/120 Volt AC outlet for 99598. Once operating,
the discharge rate may be adjusted by turning the
discharge control at end of hose.
Spray Adjustment: The "fine" (unpressurized) setting
has an adjustment rate of 1.5 to 3.5 gallons/hr. On
"heavy" (pressurized) setting, the adjustment rate is
6 to 14 gallons/hr. Spray direction is variable through
manipulation of the discharge hose.
©2018 Manufactured by H. D. Hudson Manufacturing Company
99599
Wettable Powders: Preliminary testing is
recommended to insure that desired rate is obtainable.
Shake or agitate solution periodically to keep powders
in suspension.
After Use: When the unit is turned "off" after spraying,
siphoning action may continue for a moment, resulting
in a solid stream of spray material. To prevent this, tip
the nozzle up straight as you switch "off" the motor,
thus flushing any spray solution remaining in the
discharge line back into the canister. To store the 99598
or change spray materials, detach the sprayer from the
canister, immerse the supply tube in clear water, and
flush until no residue can be seen in the supply tube.
Wash the canister thoroughly
SERVICE AND MAINTENANCE
Clean and dry your sprayer after every use to greatly
prolong its useful service life. Many spray materials
will harden if left in the sprayer and plug up the
nozzle, shut-off valve or supply tube. The soft parts,
O-rings and gaskets, will ultimately wear out and need
replacing, just like the oil filter on your car, for example.
How often they need replacing depends on how much
you spray, the spray materials you use and whether
or not the sprayer is regularly cleaned after use. Call
1-800-9-SPRAYER or visit www.hdhudson.com to obtain
genuine Hudson® replacement parts. If you leave
your sprayer in the garage over Winter, particularly in
northern areas, the soft parts may dry out and need
servicing before you use your sprayer for the first time
in the Spring.