Pad Replacement
1. Remove back section and disconnect
water line (see Step 1 under assembly.)
NOTE: Proper orientation of the media is
critical to ensure cooling effectiveness.
2. Install the media pad so that the
steeper angle of the flute slopes down
toward the bottom of the media frame.
3. Insert the stems through the four
screw holes in the media frame.
4. Push stems through the media and
fasten media in place with the four
keepers. Take care not to damage the
media.
5. Reattach water line to media frame.
6. Reinstall media frame onto the body
using two screws.
End of Season Servicing
1. Accomplish Regular Servicing procedures. Ensure unit is fully drained of water.
2. Carefully inspect media to verify media is not crushed, broken and clogged or
heavily encrusted with minerals. If so, dispose and replace media pad.
3. Clean interior with clean water. Wipe down outside with clean damp cloth.
4. Store in safe, dry place. Do not store with water in reservoir.
Trouble shooting :
PROBLEM
Pump is not working
Fan not operating
Unit is not cooling as
well as previously
PROBABLE CAUSE
Unit may be out of water
Pump may be defective
No power supplied.
Insufficient air flow
(input and exhaust.)
Clogged or dirty media
7
45°
15°
Fill reservoir with water
and activate pump.
Replace pump
Verify unit is plugged into
a 120V power outlet and
turned on.
Check fuse or breaker.
If connected to GFCI
outlet, check if tripped and
reset.
Ensure windows/doors
are open for correct air
flow.
Check media pad and wash
or replace as necessary.
REMEDY