MobileView Tablet Power Kit
Battery Status
Display/Operation
CHARGE
READY
Publication 2727-IN007B-MU-P
Charging
Battery/Charger contacts should always be clean.
TIP
Dirty contacts can result in a battery charger
malfunction. To clean contacts use a pencil eraser or
an alcohol swab.
1. Set Smart Charger on a flat surface. Plug AC adapter into outlet.
2. Plug power supply adapter into charger.
3. Insert battery into the battery holder.
Within 15 seconds, battery charging LED flashes when voltage drops
below 6 volts.
After an additional 3 seconds, if battery is within voltage and
temperature parameters, charge LED will illuminate signaling charge is
in progress. Charge cycle is complete when ready green light is lit.
Battery Fault
A battery fault condition has occurred if the yellow Charging LED
continues to flash. This could be caused by a defective, over
discharged or hot battery. If the battery is over discharged, allow the
battery to sit on the charger for 15 minutes, then remove the battery
and reinsert. A hot battery should be allowed to cool and be
reinserted. If the LED continues to flash, the battery is defective. The
battery should be analyzed by a battery technician or disposed of
properly. Contact your local waste management officials for
information regarding collection, recycling, and disposal of
Lithium-Ion batteries.
New Batteries
When charging battery packs that are new or have been on a shelf for
an extended period of time, the charger may prematurely switch to
ready. If this occurs, remove the battery from the charging bay and
reinsert. This may take 3 to 4 cycles to adequately form battery pack.