1. About this document
Please read carefully and keep in a safe place.
• Under copyright. Reproduction either in whole or
in part only with our consent.
• Subject to change in the interest of technical
progress.
Symbols
!
Hazard warning!
Reference to other information in the
...
document.
2. General safety precautions
Disconnect the power supply before
!
attempting any work on the unit.
• During installation, the electric power cable being
connected must not be live. Therefore, switch off
the power first and use a voltage tester to make
sure the wiring is off-circuit.
• Installing the LED luminaire involves work on the
mains voltage supply.
This work must therefore be carried out pro-
fessionally in accordance with national wiring
regulations and electrical operating conditions.
(e.g. DE-VDE 0100, AT-ÖVE / ÖNORM E8001-1,
CH-SEV 1000)
• Only use genuine replacement parts.
• Repairs may only be made by specialist work-
shops.
3. RS PRO LED P1 Slave /
RS PRO LED P2 Slave /
RS PRO LED P3 Slave
Proper use
– Light with LEDs as the source of light
– Suitable for indoor wall and ceiling mounting
– As single luminaire or for interconnection with the
sensor-switched master version
Package contents (Fig. 3.1)
Product dimensions (Fig. 3.2)
Product components
RS PRO LED P1 (Fig. 3.3)
RS PRO LED P2 / RS PRO LED P3 (Fig. 3.4)
A Electronics enclosure
B Connecting terminal
C Sealing plug

4. Electrical connection

• Switch OFF power supply (Fig. 4.1)
Wiring diagram (Fig. 4.1)
The mains power supply lead is a 3-core cable:
L
= phase conductor (usually black, brown or
grey)
N = neutral conductor (usually blue)
PE = protective-earth conductor (green/yellow)
If you are in any doubt, identify the conductors
using a voltage tester; then disconnect from the
power supply again. Connect phase (L) as well as
the neutral conductor (N) to the terminal.
Important:
Incorrectly wired connections will produce a short
circuit later on in the product or your fuse box. In
this case, you must identify the individual con-
ductors once again and reconnect them. A mains
power switch for turning the unit ON and OFF may
of course be installed in the mains supply lead.
The light source of this luminaire cannot be re-
placed. If the light source needs to be replaced (e.g.
at the end of its service life), the complete luminaire
must be replaced.
Note:
Do not make direct contact with the LEDs.
5. Mounting
• Check all components for damage.
• Do not use the product if it is damaged.
• When installing the LED luminaire, make sure the
installation site is not subject to vibration.
Mounting procedure
• Detach shade from enclosure.
• Mark drill holes (Fig. 5.1).
• Drill holes and fit wall plugs.
• Pierce sealing plug for power supply lead
(Fig. 5.2).
• Concealed wiring (Fig. 5.3).
• With spacers for surface mounting (Fig. 5.4).
• Connect conductors (Fig. 5.5 + 5.6).
• Switch ON power supply (Fig. 5.7).
• Fit shade (Fig. 5.7).
Light distribution curve (Fig. 5.8)
- 8 -
- 8 -
6. Disposal
Electrical and electronic equipment, accessories
and packaging must be recycled in an environmen-
G B
tally compatible manner.
1
3
Do not dispose of electrical and electronic
Y E A R
Y E A R
equipment as domestic waste.
MANUFACTURER'S
MANUFACTURER'S
WARRANTY
WARRANTY
EU countries only:
Under the current European Directive on Waste
Electrical and Electronic Equipment and its imple-
mentation in national law, electrical and electronic
equipment no longer suitable for use must be col-
lected separately and recycled in an environmentally
compatible manner.
7. Manufacturer's Warranty
As purchaser, you are entitled to your statutory
rights against the vendor. If these rights exist in your
country, they are neither curtailed nor restricted by
our Warranty Declaration. We guarantee that your
STEINEL Professional sensor product will remain
in perfect condition and proper working order for a
period of 5 years. We guarantee that this product
is free from material-, manufacturing- and design
flaws. In addition, we guarantee that all electronic
components and cables function in the proper
manner and that all materials used and their surfac-
es are without defects.
Making Claims
If you wish to make a claim, please send your prod-
uct complete and carriage paid with the original
receipt of purchase, which must show the date of
purchase and product designation, either to your
retailer or contact us at STEINEL (UK) Limited,
25 Manasty Road, Axis Park, Orton Southgate,
Peterborough, PE2 6UP, for a returns number.
For this reason, we recommend that you keep your
receipt of purchase in a safe place until the warranty
period expires. STEINEL shall assume no liability for
the costs or risks involved in returning a product.
For information on making claims under the terms
of the warranty, please go to
www.steinel-professional.de/garantie
If you have a warranty claim or would like to ask any
question regarding your product, you are welcome
to call us at any time on our Service Hotline
01733 366700.
5
Y E A R
MANUFACTURER'S
WARRANTY
- 9 -

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Rs pro led p2 slaveRs pro led p3 slave4007841056131

Tabla de contenido