Kohler STERLING 6201 Serie Guía De Instrucciones página 4

Ocultar thumbs Ver también para STERLING 6201 Serie:
Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

Roughing-In (cont.)
For showers with wall surrounds, installing accessories that require backing or support is not recommended.
Such installation could void the warranty.
If installing a shower door, refer to the shower door manufacturer's instructions for any special framing
considerations.
1. Construct the Framing
NOTE: Refer to the "Roughing-In" section for dimensions.
This receptor or shower is designed for installation in an alcove.
The stud locations must meet load bearing requirements, which are often specified by local building
codes. Studs must also allow for the installation of the plumbing fixtures and any shower door.
Install the Framing
Make sure that the end studs are aligned with the edge of the vertical end wall flanges.
Make sure that the vertical end wall flanges are 35-1/4" (89.5 cm) away from the back wall studs. If
necessary, adapt this dimension slightly for finished wall considerations.
Construct 2x4 or 2x6 stud framing according to the roughing-in information for your particular
model.
If possible, provide an access panel at the back of the plumbing wall to service the supply and
waste piping.
IMPORTANT! For showers with wall surrounds, installing accessories that require bridging or support is
not recommended. Such installations could void the warranty.
For receptor-only installations, add any backing or support needed for shelving, grab bars, towel
bars, or other accessories. Refer to the accessory manufacturer's instructions.
NOTE: For installations that include a shower door, a stud may be required to properly install the shower
door.
Make sure that the framing for each stud is plumb and square to within 1/8" (3 mm). Shimming
will be required if tolerances are not met.
NOTE: For installations with wall surrounds, do not allow fiber or other soft material to drop down into
the back channel, as this could damage the shower.
For installations with wall surrounds, cover or seal any loose material.
Construct the Floor
NOTE: The receptor basin area requires no additional support when the subfloor is plumb and level with
respect to the stud framing. If the subfloor is not level, shimming may be required to level the unit. Make
sure that the floor offers adequate support as required by local building codes.
Cut a 4-1/2" (11.4 cm) diameter hole around the drain location.
Verify that the subfloor is flat and level. If the subfloor is not level, proceed to the "Level the Floor"
subsection.
Level the Floor
The receptor supports must rest directly on a level subfloor. The following steps may be used to level an
uneven floor:
Build a dam that will keep the flooring material in the desired location.
1020187-2-F
4
Sterling

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Sterling 6202 serie

Tabla de contenido