short period. During cooling mode, if water depletes and triggers the alarm, add water to tank
through "front water inlet", and press COOL button to turn cooling function on again.
REMOTE CONTROL (Batteries not included): Open the battery compartment at the back of the
remote control and insert two new AAA dry cell batteries. Care must be taken to insert the
batteries into the correct polarity (+/-) markings shown inside the battery compartment.
Air Renewal Requirements:
When your cooler is working, it is important to leave a window or door open in order to keep a
constant air flow and to avoid any accumulation of humidity and heat. Your Evaporative Cooler
does not cool correctly when air flow is restricted from exiting a room. This causes a decrease in
the cooling efficiency due to an increase of humidity. Therefore, an opening of at least 1 square
foot for every 500 CFM of injected air is required.
7. Maintenance
WARNING
Stagnant water may cause bacterial growth and serious health problems. Do not allow
stagnant water to remain in the tank.
Drain and clean the water tank before storage, after seasonal use and whenever the unit is
not used for a long time period.
Changing the filter pads:
Please follow the instructions below in order to change the filter pads.
1- Remove the top screw (under the power cord). Remove the two screws on the bottom
of filter pad retainer.