noken SMART LIS REFLEX 100215364 Manual De Instrucciones página 17

Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 4
Press the [On/Standby] button to turn on the device or to enter the "Standby/Antifreeze" mode.
NOTE: When the device is switched to "Standby/Antifreeze" mode, it beeps twice for 0.5sec. When the device is
switched to "On" mode (i.e. it is turned on), it beeps for 1sec.
"Comfort" mode: In this mode the desired temperature of the radiator is selected. The temperature value is set
through the [+] and [-] buttons to one of the following values:
40°C, 45°C, 50°C, 55°C, 60°C, 65°C.
The rightmost lit or blinking LED in the "Comfort bar" indicates the selected temperature. A blinking LED indi-
cates that the corresponding temperature has not yet been reached during the heating phase. When a certain
temperature level is reached, the corresponding LED stops blinking and remains lit.
Example:
The device is firstly
turned on. Pressing 4
times the [+] button, the
desired temperature is
set to a value of 55°C
(the first 4 LEDs from the
left start blinking).
"Standby/Antifreeze" mode: In this mode the device goes in standby, however as soon as the temperature of
the liquid of the radiator falls below 10°C, the heating element is automatically powered on.
"Boost" mode: Press the [Boost/Timer] button to activate this operative mode.
This mode activates the heating element to the maximum power for 2hrs (for safety reasons the maximal tempe-
rature is limited to 65°C).
To exit the "Boost" mode press the [Boost/timer] button.
"Boost" mode indication: "Boost/Timer" LED has red color and it blinks
"Timer24" mode: Press the [Boost/Timer] button for 3 seconds to activate this mode.
The control system activates the "Boost" mode for 2 hours, after that it returns into "Comfort" mode and after
22 hours the "Boost" mode is started again for 2 hours. This sequence will repeat endlessly. To exit the "Ti-
mer24" mode press the [Boost/Timer] button.
NOTE: During the first cycle the duration of the "Comfort" mode is of 21 hours.
"Timer24" indication during 2hrs "Boost": "Boost/Timer" LED blinking green
During 22hrs "Comfort": "Boost/Timer" LED permanent green
"Timer12" mode: Press the [Boost/Timer] button for more than 5 seconds to activate it.
The control system activates the "Boost" mode for 2 hours, after that it returns into "Comfort" mode and after
10 hours the "Boost" mode is started again for 2 hours. This sequence will repeat endlessly. To exit the "Ti-
mer12" mode press the [Boost/Timer] button.
NOTE: During the first cycle the duration of the "Comfort" mode is of 9 hours.
"Timer12" indication during 2hrs "Boost": "Boost/Timer" LED blinking amber
During 10hrs "Comfort": "Boost/Timer" LED permanent amber
NOTE: For safety reasons, the maximal temperature of the radiator during the 2hrs boost is limi-
ted to 65°C.
The radiator starts
heating. When the tem-
perature of the radiator
reaches 40°C the first
(blue) LED stops blinking
and remains lit.
After some time, the
temperature
reaches 45°C and the
second (green) LED
also stops blinking and
remains lit
ENG
The same behavior
applies to the two
subsequent (yellow)
LEDs, until the desired
temperature of 55°C is
reached (all LEDs stop
blinking).
17

Publicidad

Tabla de contenido
loading

Tabla de contenido