STEP 4:
FLANGE & SEAL INSTALLATION
FLANGE EVEN WITH OR UP TO 1/4" BELOW
FLOOR INSTALLATION
A:
INSTALL SPACER OVER FLANGE.
Slide seal holes over bolts.
Important: Foam side of spacer
must face down as pictured or
leaks may occur.
B:
INSTALL SEAL ON TOP OF
SPACER.
Slide bolt holes over bolts.
Proceed to Step 5.
FLANGE MORE THAN 1/4" BELOW FLOOR INSTALLATION
NOTE: For a flange depth greater than ½" a flange extender is
required. (2nd seal purchased separately)
A:
INSTALL TWO SEALS ON TOP
OF SPACER.
Slide spacer holes over bolts. Then
slide each of the seal bolt holes
over bolts. Important: Foam side
of spacer must face down as
pictured or leaks may occur.
Proceed to Step 5.
8
STEP 5: TOILET INSTALLATION
(CONTINUED)
A:
STEP 6: SECURE TOILET
A:
B:
SET BOWL.
Position toilet bowl over seal, guiding holes in toilet base
over bolts.
NOTE: Toilet can be repositioned on seal, if needed, unlike traditional
wax rings.
NOTE 2: If toilet rocks, do not force by overtightening the bolts. Locate
shims to firmly secure toilet (see next page).
INSTALL THREADED CAP BASE
ONTO BOLT, FLAT SIDE DOWN.
PLACE ANTI-SPIN WASHER
INSIDE THREADED CAP BASE.
Threaded
Cap Base
Anti-Spin
Washer