3.4 FAULTS
The heater is equipped with an advanced self-diagnostic system. If a problem arises with
the unit, the fault symbol will flash on the screen and the respective code will be displayed.
Some faults, identified with the letter "A," will block unit operation.
To restore operation, simply press the RESET key (4 - fig. 1) for 1 second. If the heater
does not reset, the fault must be resolved.
Faults identified by the letter "F" cause temporary blocks that are automatically resolved
when the value returns to the heater's normal operating range.

3.4.1 LIST OF FAULTS

Fault code
Fault
The burner does not
A01
ignite.
Flame signal present
A02
while the burner is off
A03
Protection activated
No flame is present after
A06
the ignition phase.
A09
Faulty gas valve
A16
Faulty gas valve
A21
Bad combustion fault
A41
Sensor position
A51
Bad combustion fault
F04
Card setting fault
Card setting fault
F05
Faulty fan
F07
Card setting fault
48
EN
Possible cause
Solution
Make sure gas is
flowing properly to the
Lack of gas
heater, and no air is
present in the pipes.
Make sure the
Faulty detection/
electrode is properly
ignition electrode
installed, connected,
and free of deposits.
Check the gas
Faulty gas valve
valve and replace if
necessary.
Gas valve wiring
Check the wiring.
interrupted
Ignition power too
Adjust the ignition
low
power.
Check the ionization
Faulty electrode
electrode wiring.
Faulty card
Check the card.
Check the position
Faulty DHW sensor
and operation of the
DHW sensor.
No water is
Check the flow switch.
circulating.
Low pressure on the
Check the gas
gas network
pressure.
Minimum burner
Check the pressures.
pressure adjustment
Wiring interrupted
Check the wiring.
Check the gas
Faulty gas valve
valve and replace if
necessary.
Wiring interrupted
Check the wiring.
Check the gas
Faulty gas valve
valve and replace if
necessary.
Fault F20 generated
6 times in the last
See fault F20.
10 minutes
DHW sensor
Check the position
detached from the
and operation of the
pipe
sensor.
Obstruction of
the aspiration/
Check the flue.
evacuation duct
Incorrectly
Check the card
configured card
setting and change if
setting
necessary.
Incorrectly
Check the card
configured card
setting and change if
setting
necessary.
Wiring interrupted
Check the wiring.
Faulty fan
Check the fan.
Faulty card
Check the card.
Incorrectly
Check the card
configured card
setting and change if
setting
necessary.
Fault code
Fault
F10
Faulty DHW 1 sensor
F14
Faulty DHW 2 sensor
F20
Combustion control fault
Supply voltage under
F34
180 V.
F42
Faulty DW sensor
F50
Faulty gas valve
code A73022090
SKY ECO F
Possible cause
Solution
Defective sensor
Short-circuited
Check the wiring or
wiring
change the sensor.
Wiring interrupted
Defective sensor
Short-circuited
Check the fan and the
wiring
respective wiring.
Wiring interrupted
Check the fan and the
Faulty fan
respective wiring.
Check the diaphragm
Incorrect diaphragm
and replace if
necessary.
Flue badly sized or
Check the flue.
obstructed
Problems in the
Check the electrical
electrical network
installation.
Defective sensor
Change the sensor.
Modulating actuator
Check the wiring.
wiring interrupted
Check the gas
Faulty gas valve
valve and replace if
necessary.