LIST OF FAULTS

Fault
Fault
The burner does not
A01
ignite.
Flame signal present
while the burner is
off
A03
Protection activated
A06
after the ignition
phase.
A09
Faulty gas valve
A16
Faulty gas valve
Bad combustion fault
A41
Sensor position
A51
Bad combustion fault Obstruction of the aspiration/evacuation duct
F04
Card setting fault
Card setting fault
F05
Faulty fan
F07
Card setting fault
F10
sensor
F14
sensor
Combustion control
fault
Supply voltage under
F34
F50
Faulty gas valve
EN
Lack of gas
Faulty detection/ignition electrode
Faulty gas valve
Ignition power too low
Faulty electrode
Faulty card
No water is circulating.
Low pressure on the gas network
Minimum burner pressure adjustment
Faulty gas valve
Faulty gas valve
minutes
Faulty fan
Faulty card
Defective sensor
Short-circuited wiring
Defective sensor
Short-circuited wiring
Faulty fan
Incorrect diaphragm
Flue badly sized or obstructed
Problems in the electrical network
Defective sensor
Modulating actuator wiring interrupted
Faulty gas valve
cod. 3541S170 - Rev. 00 - 02/2019
Solution
no air is present in the pipes.
Make sure the electrode is properly installed,
connected, and free of deposits.
Check the gas valve and replace if necessary.
Check the wiring.
Adjust the ignition power.
Check the ionization electrode wiring.
Check the card.
Check the gas pressure.
Check the pressures.
Check the wiring.
Check the gas valve and replace if necessary.
Check the wiring.
Check the gas valve and replace if necessary.
See fault F20.
Check the position and operation of the sensor.
Check the card setting and change if necessary.
Check the card setting and change if necessary.
Check the wiring.
Check the fan.
Check the card.
Check the card setting and change if necessary.
Check the wiring or change the sensor.
Check the fan and the respective wiring.
Check the fan and the respective wiring.
Check the diaphragm and replace if necessary.
Check the electrical installation.
Change the sensor.
Check the wiring.
Check the gas valve and replace if necessary.