Special Features; Control Panel - Friedrich Hazardgard SH15 Instrucciones De Instalación Y Funcionamiento

Ocultar thumbs Ver también para Hazardgard SH15:
Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

Hazardgard Special Features
Permanent Split-Capacitor, totally enclosed fan motor to
assure efficient operation even under adverse electrical
conditions. Motor has a special stainless steel shaft to resist
corrosion and a hermetically sealed overload for arc-free
operation.
High capacity compressor with internal hermetically sealed
overload.
Solid-state printed circuit board insulated against corrosion
on conductor paths. Contains transient voltage suppressor
to protect controls against transient voltage spikes. Provides
solid state switches for arc-free operation.
Hot gas bypass low ambient control to permit operation
without freezing at outdoor ambient temperatures as low
as 45°F (7°C).
Environmentally sealed on-off switch and gold plated
contacts in thermostat for corrosion resistance.
Electrodeposited epoxy primer and alkyd enamel, both
oven-baked for an attractive, long-lasting finish.
Friedrich Air Conditioning quality has been proven by more than 25 years of successful experience from the Gulf of Mexico to
the searing sands of the Arabian desert.

Control Panel

Function Control (Power)
This switch is a double pole, single throw toggle switch.
ON - Turns everything on.
OFF - Turns everything off.
Temperature Control
The knob at the bottom is the thermostat which is a cross ambient
type used to maintain the desired comfort level. The thermostat
reacts only to a change in temperature at the bulb location - turn
the knob clockwise to set cooler, counterclockwise for warmer.
Exclusive
Friedrich leads with the first UL Listed Room Air Conditioners
designed to cool living quarters and other enclosures situated in
hazardous locations where specific volatile flammable liquids or
gases are handled or used with enclosed containers or systems.
Friedrich Hazardgard room air conditioners are designed to
meet the National Electrical Code, Article 500 requirements
for Class I, Division 2, Groups A, B, C, D Hazardous locations,
and are the only air conditioners UL Listed for this application.
THIS UNIT IS LISTED BY UNDERWRITERS LABORA-
TORIES FOR USE IN CLASS I, DIVISION 2, GROUPS A,
B, C, D HAZARDOUS LOCATIONS. Operating Temperature
Code: T3B.
920-024-06
Copper tubing/aluminum fin coils.
Galvanized steel cabinet and base pan, all bonderized.
Slide-out chassis for easy installation in window or
through–the–wall.
Extra insulation inside, including completely insulated
plenum chamber for quieter, more efficient cooling.
Entire unit test run in environmental chamber before
crating.
Eight–way air flow control for uniform air circulation.
Patented electronic control circuit.
Condensate drain with exclusive mosquito trap.
15ampcircuitwithtime-delayfuserequired. Accommodates
direct wiring.
Long lasting 3/8" (10 mm) thick air filter, germicidally
treated, easily removed for cleaning.
5

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Hazardgard sh20

Tabla de contenido