General; Intended Use; Product Description; Assembly - Etac Swift Mobil-2 Manual

Ocultar thumbs Ver también para Swift Mobil-2:
Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 39

General

Thank you for choosing an Etac product.
In order to avoid injury during handling and use, please read through
this manual first.
In the manual, the user is the person sitting in the chair. The carer is
the person helping the user.

Intended use:

The Swift Mobile 2 family is a range of mobile shower chairs and
toilet chairs (hereafter called the product) intended for indoor use
when performing hygiene tasks for people with restricted mobility.
The product can be used in the shower, at a sink, or over the toilet,
as well as for transfers to and from the hygiene room.
The product is intended for use in home environments and
institutions.
The product is suitable for use in wet areas, but not pools or similar
corrosive environments.
The product is intended to compensate for various types of injuries
or disabilities that limit the mobility of the user.
The product is intended for adult users, generally persons who are
at least 146 cm tall and who weigh at least 40 kg.
The product is not intended for any other use or environment
beyond those stated above.
The product has been tested and complies with the requirements set
out in EN ISO 10993-1 and SS EN 12182.

Product description

A1. Bolt, A2. Leg support, A3. Seat, A4. Arm support, A5. Back support upholstery
A6. Head support

Assembly

Technical data

Warranty / maintenance

5-year guarantee against material and manufacturing defects. For
terms and conditions, see www.etac.com.
Service life 7 years. For complete information regarding the service life
of the product, see www.etac.com.
D1. Clean the product with normal non-abrasive cleaning agents (pH
value of between 5-9). Rinse and dry.
Disinfect the product with an alcohol-based disinfectant, 70%.
The product is otherwise maintenance-free.
D2. The product and its accessories can be safely cleaned at 85°C for
3 minutes (unless otherwise stated). This applies for recondition-
ing.

Safety

• Defective chairs must not be used.
E1. Make sure the castors are locked when users sit down on or get up
from the chair.
• An anti-tip attachment must be used if the user is an amputee.
E2. Never stand on the foot supports as there is a risk of tipping!
English
Contra indications:
There are no known contraindications.
This symbol appears in the manual along with text. It
indicates instances where the safety of the user or the
assistant may be at risk.
The images which are referred to on each page are found
at the start of the manual (pages 3 to 11). See Figures A
to J for the corresponding text.
This product should be recycled as per national
regulations.
Item list:
= Applies to,
= Accessories
See the item list on the right which displays the information applicable to
each product.
The product can be reconditioned. Refer to the reconditioning instruc-
tions at www.etac.com.
Constituent materials are resistant to common disinfectants.
The following surface treatment methods have been used to protect
against corrosion:
Lacquered surfaces = Polyester powder coating
Non-lacquered steel surfaces = Fe/Zn-Ni
Reuse:
The product is suitable for reuse. The number of times it can be reused
depends on how often and in which way the product is used. Before
reuse, thoroughly clean and disinfect the product and check its safety
features. If necessary, take remedial action.
E3. The sitting position has an impact on stability.
E4. Chair stability is improved if the castors point outward.
E5. See the maximum user weight for your commode chair in the table
(page 5).
E6. Risk of crushing with arm supports.
E7. Do not use defective products.
21
Etac / Swift Mobil / www.etac.com
See Figure A
See Figure B
See Figure C
See Figure D
See Figure E

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Swift mobil 24-2Swift mobil tilt-2Swift mobil-2 xlSwift mobil tilt-2 xl

Tabla de contenido