4.2

Preparing refrigerant piping

4.2.1

Refrigerant piping requirements

Refrigerant piping diameter
Use the same diameters as the connections on the outdoor units:
Class
L1 liquid piping
20~35
Ø6.4
50+60
Ø6.4
71
Ø6.4
Use the same diameters as the connections on the outdoor units:
Class
L1 liquid piping
15~35
Ø6.4
42+50
Ø6.4
Refrigerant piping material
▪ Piping material: Phosphoric acid deoxidised seamless copper.
▪ Flare connections: Only use annealed material.
▪ Piping temper grade and thickness:
Outer diameter
Temper grade
(Ø)
6.4 mm (1/4")
Annealed (O)
9.5 mm (3/8")
12.7 mm (1/2")
15.9 mm (5/8")
(a)
Depending on the applicable legislation and the unit's
maximum working pressure (see "PS High" on the unit
name plate), larger piping thickness might be required.
4.2.2

Refrigerant piping insulation

Pipe outer diameter
Insulation inner
)
diameter (Ø
p
6.4 mm (1/4")
8~10 mm
9.5 mm (3/8")
12~15 mm
12.7 mm (1/2")
14~16 mm
15.9 mm (5/8")
16~20 mm
Ø
Ø
i
i
Ø
Ø
p
p
t
If the temperature is higher than 30°C and the humidity is higher
than RH 80%, the thickness of the insulation materials should be at
least 20  mm to prevent condensation on the surface of the
insulation.
5

Installation

5.1

Opening the units

5.1.1

To open the indoor unit

To remove the front panel
1 Hold the front panel by the panel tabs on both sides and open
it.
(A)(F)TXP20~35L2V1B + FTXF20~71A2V1B
Daikin room air conditioner
3P512025-1 – 2017.11
L1 gas piping
Ø9.5
Ø12.7
Ø15.9
L1 gas piping
Ø9.5
Ø12.7
(a)
Thickness (t)
Ø
≥0.8 mm
t
Insulation thickness
)
(t)
i
≥10 mm
a
Indentation on the unit
2 Remove the front panel by sliding it to the left or the right and
pulling it toward you.
Result: The front panel shaft on 1 side will be disconnected.
3 Disconnect the front panel shaft on the other side in the same
manner.
a
a
Front panel shaft
To re-install the front panel
1 Attach the front panel. Align the shafts with the slots and push
them all the way in.
2 Close the front panel slowly and press on both sides at the
centre.
To remove the front grille
CAUTION
Wear adequate personal protective equipment (protective
gloves, safety glasses,...) when installing, maintaining or
servicing the system.
1 Remove the front panel to remove the air filter.
2 Remove 2 screws (class 20~35) or 3 screws (class 50~71) from
the front grille.
3 Push down the 3 upper hooks marked with a symbol with 3
circles.
b
a
a
Upper hook
b
Symbol with 3 circles
4 We recommend opening the flap before removing the front
grille.
5 Place both hands under the centre of the front grille, push it up
and then toward you.
5 Installation
a
a
Installation manual