5 Installation
To re-install the front grille
1 Install the front grille and firmly engage the 3 upper hooks.
2 Install 2 screws (class 20~35) or 3 screws (class 50~71) back
on the front grille.
3 Install the air filter and then mount the front panel.
To remove the electrical wiring box cover
1 Remove the front grille.
2 Remove 1 screw from the electrical wiring box.
3 Open the electrical wiring box cover by pulling the protruding
part on the top of the cover.
4 Unhook the tab on the bottom and remove the electrical wiring
box cover.
a
b
a
c
Installation manual
8
a
Tab
b
Protruding part on the top of the cover
c
Screw
5 To re-install the cover, first hook the bottom tab onto the
electrical wiring box, and slide the cover into the 2 upper tabs.
To open the service lid
1 Remove 1 screw from the service lid.
2 Pull out the service lid horizontally away from the unit.
a
Service lid screw
b
Service lid
5.2

Mounting the indoor unit

5.2.1

To install the mounting plate

1 Install the mounting plate temporarily.
2 Level the mounting plate.
3
3 Finish the installation by securing the mounting plate on the wall
using screws.
4 Use a tape measure. Position the end of tape measure at
symbol " ".
INFORMATION
The removed pipe port cover can be kept in the mounting
plate pocket.
a
a
b
(A)(F)TXP20~35L2V1B + FTXF20~71A2V1B