3. Installation Preparation.
To prevent personal injury and damage, ensure
that the hanging location allows the blades a
clearance of 7 feet (2.13m) from the floor and
30in. (76cm) from any wall or obstruction.
This fan is suitable for room sizes up to 225
square feet (20.9 square meters).
This fan can be mounted with a downrod
on a regular (no-slope) or vaulted ceiling. The
hanging length can be extended by purchasing
a longer downrod (0.5in. /1.27cm diameter).
Other installation, such as flushmount, is not
available for this fan.
Installation requires these tools:
Phillips screwdriver, flat-head screwdriver,
adjustable pliers or wrench, stepladder, wire
cutters, and rated electrical tape.
4. Hanging Bracket Installation.
Turn off circuit breakers to current fixture from breaker
panel and be sure operating light switch is turned to the
OFF position.
WARNING: Failure to disconnect power supply prior to
installation may result in serious injury.
Remove existing fixture.
WARNING: When using an existing outlet box, be sure the
outlet box is securely attached to the building structure and can
support the full weight of the fan. Ensure outlet box is clearly
marked "Suitable for Fan Support." If not, it must be replaced
with an approved outlet box. Failure to do so can result in
serious injury.
CAUTION: Be sure outlet box is properly grounded and that a
ground (GREEN or bare) wire is present.
Partially loosen screws in slotted holes of canopy. Remove
the other 2 screws--save for later use. Twist canopy to
remove hanging bracket from canopy.
Install hanging bracket to outlet box, using original screws,
spring washers and flat washers provided with new or
original outlet box.* If installing on a vaulted ceiling, face
opening of hanging bracket towards high point of ceiling.
Arrange electrical wiring around the back of the hanging
bracket.
*Note: It is very important that you use the proper hardware
when installing the hanging bracket as this will support the fan.
blade edge
30
inches
7 feet
(76cm)
(2.13m)
downrod
installation
hanging bracket
flat washers
spring washers
outlet box screws
page 3
12 ft. - 15 ft.
(3.66m - 4.57m)
flushmount
installation
Vaulted ceiling
angle is not to
exceed 25 degrees.