Electrical Specifications; Troubleshooting - Simer OD6601G Manual De Uso Y Manutención

Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 10
GB

ELECTRICAL SPECIFICATIONS

Series
OD6601
2533
PERFORMANCE
LPM (GPM) AT TOTAL METERS (Feet)
0m
Series
(0')
OD6601
70
2533
(18.5)

TROUBLESHOOTING

Fault
Pump won't start
or run
Pump won't shut off Restricted discharge
(obstacle or ice
in piping)
Pump operates but
delivers little or
no water.
Motor
HP
Watts
1/6
400
1/6
400
1.5m
3m
(5')
(10')
55
40
(14.5)
(10.5)
Probable Cause
Pump is not plugged in
Blown fuse
Low Line Voltage
Defective motor
Restricted intake
Low line voltage
Worn or defective parts
or plugged impeller
Restricted intake
Individual
Branch Circuit
Req. in Amps
15
15
4.6m
6.1m
(15')
(20')
21
4
(5.5)
(1)
Remedy
Check to make sure that the pump is
plugged into the correct outlet
Replace with fuse of correct size
Check wire size from main switch on
property. If it is OK, contact power
company
Replace the pump
Remove the pump and clean the
pump and piping
Remove the pump and clean
the intake
Check wire size from main switch on
property. If it is OK, contact power
company
Replace the pump
Clean out the intake screen
4

Publicidad

Tabla de contenido
loading

Tabla de contenido