Electrical Specifications; Troubleshooting - Simer OD660IG Manual Del Usuario

Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 10
GB

ELECTRICAL SPECIFICATIONS

Motor HP
1/4
PERFORMANCE
LPM (US GPM) AT TOTAL METERS (Feet)
0m (0')
1.5m (5')
80 (21)
64 (17)

TROUBLESHOOTING

Fault
Pump won't start
or run
Pump operates but
does not pump
Pump operates but
delivers little or
no water.
Power
Consumption [W]
400
3m (10')
47 (12.5)
Probable Cause
Pump is not plugged in
Blown fuse
Defective motor
Blocked discharge hose
Blocked screen
Kinked discharge hose
Worn or defective parts
or plugged impeller
Restricted intake
Fuse (delay)
[A]
10
4.6m (15') 5.5m (18')
22.7 (6)
0 (0)
Remedy
Check to make sure that the pump is
plugged into the correct outlet.
Replace with fuse of correct size with
line voltage.
Replace the pump.
Remove the pump and and clean
discharge hose.
Remove the pump and clean
the screen.
Check the installation of the hose.
Replace the pump.
Clean out the intake screen.
4

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Od660ichOd660iuk2533sh

Tabla de contenido