Descargar Imprimir esta página

CAMP CHEF FLAT TOP GRILL Instalación Y Advertencias De Seguridad página 9

Publicidad

Idiomas disponibles

Idiomas disponibles

4. Repeat steps 2–3 for lighting each burner. If burner does
not ignite, wait 5 minutes, see "Match Lighting the Main
Burners" section.
5. To turn off, turn each control knob clockwise until it locks
in the "OFF" position. This does not turn off the gas flow
from the cylinder.
Note: If burner does not light or flame is too low, you may
have spider or other insect blockage in burner. See "Burner
Assembly/Maintenance"
Match Lighting The Main Burners
1. Turn the burner control knobs to "OFF".
2. Place a paper match in the end of the match lighter.
Strike the match and place through lighting hole in the
left hand side of the grill to approximately 1/2" (1 to 2
cm) from the burner.
3. Turn on the FAR LEFT burner control knob to the "HIGH"
position. The burner should light within 5 seconds.
4. If the burner does not light, turn the control knob to
"OFF" and wait 5 minutes for gas to dissipate and
repeat lighting procedure.
5. Once lit, light adjacent burners in sequence by pressing
in and rotating the control knob to the "HIGH" position.
6. If the burner does not light within the first few attempts
of match lighting, there is a problem with the gas
supply. Turn off the gas at the burner and cylinder. DO
NOT attempt to operate the grill until the problem is
found and corrected.
Match Ignition Hole
Turning LP Cooker Off
• Turn all knobs to OFF position.
• Turn LP tank OFF by turning hand-wheel clockwise to a
full stop.
Burner Flame Check
• Light burner; rotate knob(s) from HIGH to LOW. You
should see a smaller flame in LOW position than seen on
HIGH. Always check flame prior to each use. A blue flame
with little or no yellow flame provides the best heat.
Cleaning The Burner
NOTE: Spiders and small insects can spin webs and build
nests inside the burner. This especially occurs in late
summer and fall before frost when spiders are most active.
These nests can obstruct gas flow and cause a fire in
and around the burner and orifice. Such a fire can cause
operator injury and serious damage to the appliance. To
help prevent a blockage and ensure full heat output, clean
and inspect burner tube often (once or twice a month).
NOTE: Water or air pressure will not normally clear a spider
web.
All cleaning and maintenance should only be done when
the appliance is cool and with the fuel supply turned
off at the LP cylinder. DO NOT clean any part in a self-
cleaning oven. The extreme heat will damage the finish.
Burner Assembly/Maintenance
• Although your burners are constructed of stainless steel,
they may corrode as a result of the extreme heat and
acids from cooking foods. Regularly inspect the burners
for cracks, abnormal holes, and other signs of corrosion
damage. If found, replace the burner.
• DO NOT obstruct the flow of combustion and ventilation
air. Burner tubes can become blocked by spiders and
other insects building their nests. Blocked burner tubes
WARNING