Care And Maintenance; Troubleshooting - LF Project Source F8F1C044CP Manual Del Usario

Tabla de contenido

Publicidad

CARE AND MAINTENANCE

• Clean periodically with a soft cloth. Avoid abrasive cleaners, steel wool and harsh chemicals as
these will dull the finish and void your warranty.

TROUBLESHOOTING

PROBLEM
Leak from under handle.
Aerator has an inconsistent
water flow pattern.
Water leaks from aerator.
Leaks around base of spout.
Side spray does not function.
POSSIBLE CAUSE
Retainer nut has come loose.
O-ring on cartridge is dirty or
damaged.
Aerator is dirty or misfitted.
Seats need to be replaced.
O-ring set should be replaced.
Spray diverter has stopped
functioning properly.
9
CORRECTIVE ACTION
Tighten the retainer nut. Clean
or replace O-ring.
Remove aerator, check for
debris in the aerator screens,
and confirm the rubber washer
is properly installed.
Determine if the drip is hot
or cold. Disassemble correct
handle and cartridge. Remove
rubber seat from inside of the
faucet body and replace with
new one. Reassemble cartridge
and handle.
Turn off water supply. Remove
spout trim cap. Pull spout
straight up. Replace the o-ring
set located on the body of the
faucet. Re-assemble.
Turn off water supply. Remove
spout trim cap. Pull spout
straight up. Remove the spray
diverter located in the body of
the faucet. Replace the spray
diverter in the same position
and re-assemble spout.

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

0756558

Tabla de contenido