Handle
Bonnet
Stop Tab
Mounting
Nut
7. Adjust the Maximum Water Temperature
NOTE: Prior to adjustment, make sure the handle is in the
maximum hot position.
Remove the handle and bonnet.
Turn on the water to the maximum hot water temperature by
pushing the valve stem up, and turning it fully clockwise.
Use a pencil or marker to mark the current position of the
temperature stop tab (top edge) on the mounting nut. Lift both
the indexer and the top disc just enough to clear the splines and
to allow rotation.
NOTE: Each indexer notch is an average 9.5°F (5.3°C) change in
temperature.
Turn the indexer, top disc, and valve stem counterclockwise until
you achieve the desired temperature.
Reinstall the indexer and top disc to the valve. Make sure the top
disc is snapped fully into the indexer.
Turn off the water, and reinstall the bonnet and handle.
1010442-2-D
Cap
Screw
O-Ring
Valve Stem
Top Disk
Indexer
Splines
8
Kohler Co.