DC voltage measurement / V=

Use the selector switch to set the appropriate range. Insert the
black test lead into the 'COM' socket and the red test lead into
the V/Ω/TEMP/CAP socket. Using the test probes, touch the
test points of the test object. Read measurement value on the
display. The polarity of the voltage will also be displayed.
DC voltage
Measurement
range
200 mV
2 V
20 V
200 V
600 V
-
Input resistance: 10 MΩ
-
Max. input voltage: 600 V DC

AC voltage measurement / V~

Use the selector switch to set the appropriate range. Insert the
black test lead into the 'COM' socket and the red test lead into the
V/Ω/TEMP/CAP socket. Using the test probes, touch the test
points of the test object. Read measurement value on the display.
AC voltage
Measurement
range
200 mV
2 V
20 V
200 V
600 V
Resolution
0.1 mV
0.001 V
0.01 V
0.1 V
1 V
Resolution
1 mV
0.001 V
0.01 V
0.1 V
1 V
Accuracy
± 0.5 % of reading + 1 digits
± 0.5 % of reading + 3 digits
± 0.8 % of reading + 3 digits
Accuracy
± 1.2 % of reading + 5 digits
± 1 % of reading + 5 digits
± 1.2 % of reading + 5 digits