Diode Test; Continuity Testing - Berner 313 Manual De Instrucciones

Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 55
Measurement
range
200 Ω
2 kΩ
20 kΩ
200 kΩ
2 MΩ
20 MΩ
-
Measuring voltage: 0.25 V.

Diode test

With the selector switch set to "
lead into the 'COM' socket and the red test lead into the
V/Ω/TEMP/CAP socket. Using the test probes, touch the test
points of the test object. Red test lead = anode, black test
lead = cathode. The forward voltage drop is displayed.
Measurement
range
-
Forward current: approx. 25 µA, reverse voltage: approx.
2.8 V.

Continuity testing

With the selector switch set to "
lead into the 'COM' socket and the red test lead into the
V/Ω/TEMP/CAP socket. Using the test probes, touch the test
points of the test circuit. An acoustic signal is emitted if a re-
sistance under 70 Ω is measured.
Important: Isolate from the power supply and dis-
charge capacitors in the circuit to be measured.
Resolution
0.1 Ω
1 Ω
10 Ω
100 Ω
1 kΩ
0.01 MΩ
Resolution
1 mV
33
Accuracy
± 1 % + 5 digits
± 1 % + 5 digits
± 1.8 % + 5 digits
/ ◦))". Insert the black test
Display
Forward voltage
/ ◦))". Insert the black test

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

185139

Tabla de contenido