Electrical installation and configuration
Fig. 2: PIN assignment
M12 plug 5-pin
Tab. 1: Pin assignment
30
© SICK AG • Industrial Safety Systems • Germany • All rights reserved
Electrical installation and
configuration
During the electrical installation of the C2000 Eco safety light curtain, observe the follow-
ing notes in addition to the information in the "C2000 Safety Light Curtain" operating
instructions:
To ensure full electromagnetic compatibility (EMC), functional earth (FE) must be
connected.
Sender
Pin no.
Colour
Designation
Sender
1
Brown
24 V DC
2
White
Test
3
Blue
GND
4
Black
nc
5
Grey
Shield
Receiver
1
Brown
24 V DC
2
White
OSSD 1
3
Blue
GND
4
Black
OSSD 2
5
Grey
Shield
5.1
Device configuration
The device configuration is described in the following chapters of the "C2000 Safety Light
Curtain" operating instructions:
chapter 5.4.1 Configuration of the device self test
chapter 5.4.2 Configuration of the cyclic system test
the functions
beam coding
EDM (external device monitoring)
RES (restart interlock)
are not available on the C2000 Eco safety light curtain.
Addendum Operating Instructions
Receiver
Meaning (I = input, O = output)
Voltage supply U
B
I: device self-test
0 V = sender inactive
24 V = sender active
0 V DC, voltage supply
Reserved
Functional earth
Voltage supply U
B
O: output signal switching device 1
0 V DC, voltage supply
O: output signal switching device 2
Functional earth
8011905/TI60/2010-02-12
C2000 Eco
Subject to change without notice