About this document
This document is an original document.
This addendum only applies
to the C2000 Eco safety light curtain with one of the following entries on the type label
in the Operating Instructions field:
– 8011905
– 8011905/TI60
in conjunction with the original operating instructions "C2000 Safety Light Curtain"
(SICK part number 8009140).
If not otherwise revised in this document, the information in the original operating
instructions applies, which relate to the C2000 Standard safety light curtain.
When using the C2000 Eco safety light curtain, observe the following notes in addition
to the information in the operating instructions for the C2000 safety light curtain.
The C2000 Eco safety light curtain, as a member of the C2000 product family, complies
with the requirements in accordance with EN 61 496:1, type 2.
This chapter provides information on the special features and properties of the
C2000 Eco safety light curtain. It also describes the properties and functions that differ
from the C2000 Standard.
Please read this chapter before mounting, installing and commissioning the device.
3.1
Technical specifications
The following list contains information only concerning the C2000 Eco safety light curtain
that is not already given in the original operating instructions.
protective field height: 150-1200 mm
scanning range: 0 ... 6 m
resolution: 30 mm
no beam coding
no external device monitoring (EDM)
no restart interlock (RES)
enclosure rating IP 54 (EN 60 529)
2 monitored outputs, PNP, switching current 250 mA
Addendum Operating Instructions
C2000 Eco
8011905/TI60/2010-02-12
Subject to change without notice