HOOD bODy MOUNTING
• Firstly, it is necessary to adjust the two Vr-screws
of the 11a-brackets, at minimun (B).
• Hang the hood body on the two brackets 11a.
• Connect the hood to the mains supply by means
of a bipolar switch with at least 3 mm contact
gap.
• see Part USE to open the upper panel
• Remove the metal filters by using the handles
• In order to align the hood it is necessary to
adjust the Vr-screws from inside the hood.
• Fasten the safety screw 11.
• Fit again the metal filters into their seats and
see Part USE to close the upper panel.
• Disconnect the hood from the mains supply.
Attention: If any barrier occurs in its way during
the panel opening or closing, the upper panel stops
for 1 sec and starts again the other way round. If
within 5 sec the panel does not open or close, the
motor stops. Press the key once again.
CONNECTIONS
DUCTED VERSION AIR EXHAUST SYSTEM
When installing the ducted version, connect the
hood to the chimney using either a flexible or rigid
pipe ø 150 or 120mm, the choice of which is left
to the installer.
To install a ø 150
• To install the dumper 10
• Fix the pipe in position using sufficient pipe
clamps (not supplied).
To install a ø 120
• To install a ø 120 mm air exhaust connection,
insert the reducer flange 9 on the dumper 10.
• Fix the pipe in position using sufficient pipe
clamps (not supplied)
.• Remove any activated charcoal filters.
�����
��
���
��
� � �
��
�����
�
��
7